Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2019 |
Principal Product | Treated Water and Recycled Water |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | <$500,000 |
# of Employees | 280 |
Plant Area (Sq.Ft.) | 10,500,000 |
Annual Production | 11,680,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $315,672 | 1,817,776 | kWh | $0.17 |
Electricity Demand | $443,554 | 20,784 | kW-months/year | $21.34 |
Natural Gas | $2,008,193 | 420,535 | MMBtu | $4.78 |
TOTAL ENERGY COSTS | $2,767,419 | |||
RECOMMENDED SAVINGS* | $287,489 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $111,927 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $14,931 Cost: $378 |
$14,931 | 85,976 | - | - | - | - | - | - | - | - |
$14,931 85,976 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $14,708 Cost: $260 |
$13,224 | 76,144 | $1,484 | 70 | - | - | - | - | - | - |
$13,224 76,144 kWh |
$1,484 70 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4313 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT |
Savings: $94,349 Cost: $10,000 |
$84,830 | 488,455 | $9,519 | 446 | - | - | - | - | - | - |
$84,830 488,455 kWh |
$9,519 446 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $5,414 Cost: $648 |
$5,414 | 31,172 | - | - | - | - | - | - | - | - |
$5,414 31,172 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4313 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT |
Savings: $24,937 Cost: $5,000 |
$22,421 | 129,099 | $2,516 | 118 | - | - | - | - | - | - |
$22,421 129,099 kWh |
$2,516 118 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,025 Cost: $5,039 |
$12,025 | 69,239 | - | - | - | - | - | - | - | - |
$12,025 69,239 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4313 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT |
Savings: $2,238 Cost: $3,000 |
- | - | $2,238 | 104 | - | - | - | - | - | - |
- - kWh |
$2,238 104 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $77,542 Cost: $235,055 |
$61,354 | 353,280 | $8,346 | 391 | - | - | $6,540 | - | $1,302 | - |
$61,354 353,280 kWh |
$8,346 391 kW-months/year |
- - MMBtu |
$6,540 - $ |
$1,302 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2126 LOWER OPERATING PRESSURE OF CONDENSER (STEAM) |
Savings: $41,345 Cost: $175,000 |
$47,131 | 271,385 | $5,289 | 248 | $(-11,075) | (-2,317) | - | - | - | - |
$47,131 271,385 kWh |
$5,289 248 kW-months/year |
$(-11,075) (-2,317) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $287,489 Cost: $434,380 |
$261,330 | 1,504,750 | $29,392 | 1,377 | $(-11,075) | (-2,317) | $6,540 | - | $1,302 | - | $261,330 1,504,750 kWh |
$29,392 1,377 kW-months/year |
$(-11,075) (-2,317) MMBtu |
$6,540 - $ |
$1,302 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $111,927 Cost: $244,002 |
$92,017 | 529,835 | $12,068 | 565 | - | - | $6,540 | - | $1,302 | - | $92,017 529,835 kWh |
$12,068 565 kW-months/year |
- - MMBtu |
$6,540 - $ |
$1,302 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |