Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | San Francisco State University |
---|---|
Assessment Year | 2021 |
Principal Product | Treated Water |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $50,000,000-$100,000,000 |
# of Employees | 46 |
Plant Area (Sq.Ft.) | 290,000 |
Annual Production | 4,929,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,334 | 959,776 | kWh | $0.12 |
Electricity Demand | $336,402 | 10,512 | kW-months/year | $32.00 |
Natural Gas | $262,424 | 44,087 | MMBtu | $5.95 |
Fuel Oil #1 | $128 | 5 | MMBtu | $25.60 |
TOTAL ENERGY COSTS | $710,288 | |||
RECOMMENDED SAVINGS* | $1,079,155 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $74,027 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #1 | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #1 | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,530 Cost: - |
$12 | 3,564 | $2,518 | 186 | - | - | - | - | - | - | - | - |
$12 3,564 kWh |
$2,518 186 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $8,683 Cost: $748 |
$8,683 | 74,854 | - | - | - | - | - | - | - | - | - | - |
$8,683 74,854 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,060 Cost: $149 |
$1,060 | 9,139 | - | - | - | - | - | - | - | - | - | - |
$1,060 9,139 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $192,090 Cost: $88,600 |
$131,859 | 1,136,717 | $60,231 | 1,884 | - | - | - | - | - | - | - | - |
$131,859 1,136,717 kWh |
$60,231 1,884 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $33,128 Cost: $15,421 |
$33,128 | 285,589 | - | - | - | - | - | - | - | - | - | - |
$33,128 285,589 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3323 INSTALL EMISSIONS CONTROLS TO INCREASE CAPACITY |
Savings: $352,407 Cost: $278,000 |
$280,667 | 2,419,545 | $71,740 | 2,244 | - | - | - | - | - | - | - | - |
$280,667 2,419,545 kWh |
$71,740 2,244 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $24,296 Cost: $18,341 |
$24,296 | 209,454 | - | - | - | - | - | - | - | - | - | - |
$24,296 209,454 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $77,855 Cost: $69,051 |
$77,855 | 671,169 | - | - | - | - | - | - | - | - | - | - |
$77,855 671,169 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $78,185 Cost: $114,380 |
$55,615 | 479,442 | $22,570 | 706 | - | - | - | - | - | - | - | - |
$55,615 479,442 kWh |
$22,570 706 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3142 USER BATTERY STORAGE FOR POWER QUALITY ISSUES |
Savings: $262,606 Cost: $452,925 |
- | - | $291,950 | 9,132 | $(-22,344) | (-3,754) | $(-7,000) | (-274) | - | - | - | - |
- - kWh |
$291,950 9,132 kW-months/year |
$(-22,344) (-3,754) MMBtu |
$(-7,000) (-274) MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,256 Cost: $50,039 |
$19,042 | 163,089 | $5,393 | 169 | - | - | - | - | $1,279 | - | $542 | - |
$19,042 163,089 kWh |
$5,393 169 kW-months/year |
- - MMBtu |
- - MMBtu |
$1,279 - $ |
$542 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,006 Cost: $31,025 |
$9,006 | 77,635 | - | - | - | - | - | - | - | - | - | - |
$9,006 77,635 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $11,053 Cost: $65,832 |
$11,053 | 95,287 | - | - | - | - | - | - | - | - | - | - |
$11,053 95,287 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,079,155 Cost: $1,184,511 |
$652,276 | 5,625,484 | $454,402 | 14,321 | $(-22,344) | (-3,754) | $(-7,000) | (-274) | $1,279 | - | $542 | - | $652,276 5,625,484 kWh |
$454,402 14,321 kW-months/year |
$(-22,344) (-3,754) MMBtu |
$(-7,000) (-274) MMBtu |
$1,279 - $ |
$542 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $74,027 Cost: $131,441 |
$64,295 | 556,668 | $7,911 | 355 | - | - | - | - | $1,279 | - | $542 | - | $64,295 556,668 kWh |
$7,911 355 kW-months/year |
- - MMBtu |
- - MMBtu |
$1,279 - $ |
$542 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #1 | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #1 | Personnel Changes | Ancillary Material Cost |