Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center San Francisco State University
Assessment Year 2025
Principal Product Printed Circuit Boards
NAICS 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3672 - Printed Circuit Boards
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 90,000
Annual Production 200,000 Units
Production Hrs. Annual 4,680
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $235,108 1,301,578 kWh $0.18
Electricity Demand $73,634 3,645 kW-months/year $20.20
Electricity Fees $(-181,575) - $ -
Natural Gas $26,197 1,393 MMBtu $18.81
TOTAL ENERGY COSTS $153,364
RECOMMENDED SAVINGS* $283,811 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Natural Gas Personnel Changes Primary Raw Material
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$17,052
Cost:
-
$18,252 101,068 - - - - $(-1,200) - - - $18,252
101,068
kWh
-
-
kW-months/year
-
-
MMBtu
$(-1,200)
-
$
-
-
$
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$8,005
Cost:
-
$8,005 44,325 - - - - - - - - $8,005
44,325
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$22,379
Cost:
$883
$5,901 32,676 - - $16,478 876 - - - - $5,901
32,676
kWh
-
-
kW-months/year
$16,478
876
MMBtu
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,310
Cost:
$2,631
$947 5,242 $287 14 - - $74 - $2 - $947
5,242
kWh
$287
14
kW-months/year
-
-
MMBtu
$74
-
$
$2
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$235,065
Cost:
$1,065,176
$235,065 1,301,578 - - - - - - - - $235,065
1,301,578
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$283,811
Cost:
$1,068,690
$268,170 1,484,889 $287 14 $16,478 876 $(-1,126) - $2 - $268,170
1,484,889
kWh
$287
14
kW-months/year
$16,478
876
MMBtu
$(-1,126)
-
$
$2
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Primary Raw Material Electricity Usage Electricity Demand Natural Gas Personnel Changes Primary Raw Material