Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2009 |
Principal Product | Printed, Flexible Packaging Films |
NAICS | 326111 - Plastics Bag and Pouch Manufacturing |
SIC | 2671 - Paper Coated & Laminated, Packaging |
Sales | $50,000,000-$100,000,000 |
# of Employees | 205 |
Plant Area (Sq.Ft.) | 155,000 |
Annual Production | 15,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $520,005 | 10,244,019 | kWh | $0.05 |
Electricity Demand | $143,782 | 18,018 | kW-months/year | $7.98 |
Electricity Fees | $61,956 | - | $ | - |
Natural Gas | $422,805 | 38,835 | MMBtu | $10.89 |
TOTAL ENERGY COSTS | $1,148,548 | |||
RECOMMENDED SAVINGS* | $264,405 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $137,599 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $95,326 Cost: - |
- | - | - | - | - | - | $95,326 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$95,326 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $10,684 Cost: - |
$8,801 | 172,572 | $1,883 | 236 | - | - | - | - | - | - |
$8,801 172,572 kWh |
$1,883 236 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,037 Cost: - |
$2,502 | 49,056 | $535 | 67 | - | - | - | - | - | - |
$2,502 49,056 kWh |
$535 67 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7122 DISCONNECT BALLASTS |
Savings: $2,387 Cost: - |
$1,966 | 38,544 | $421 | 53 | - | - | - | - | - | - |
$1,966 38,544 kWh |
$421 53 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,090 Cost: $460 |
$2,547 | 49,932 | $543 | 68 | - | - | - | - | - | - |
$2,547 49,932 kWh |
$543 68 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $67,595 Cost: $25,000 |
$(-5,272) | (-103,368) | $(-1,133) | (-142) | - | - | - | - | $74,000 | - |
$(-5,272) (-103,368) kWh |
$(-1,133) (-142) kW-months/year |
- - MMBtu |
- - $ |
$74,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $4,200 Cost: $2,508 |
$4,200 | 82,344 | - | - | - | - | - | - | - | - |
$4,200 82,344 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,299 Cost: $18,800 |
$20,014 | 392,448 | $4,285 | 537 | - | - | - | - | - | - |
$20,014 392,448 kWh |
$4,285 537 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $214 Cost: $183 |
$58 | 1,139 | $16 | 2 | - | - | - | - | $140 | - |
$58 1,139 kWh |
$16 2 kW-months/year |
- - MMBtu |
- - $ |
$140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $53,384 Cost: $69,621 |
- | - | - | - | $53,384 | 5,244 | - | - | - | - |
- - kWh |
- - kW-months/year |
$53,384 5,244 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $189 Cost: $642 |
$189 | 3,701 | - | - | - | - | - | - | - | - |
$189 3,701 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $264,405 Cost: $117,214 |
$35,005 | 686,368 | $6,550 | 821 | $53,384 | 5,244 | $95,326 | - | $74,140 | - | $35,005 686,368 kWh |
$6,550 821 kW-months/year |
$53,384 5,244 MMBtu |
$95,326 - $ |
$74,140 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $137,599 Cost: $21,768 |
$35,562 | 697,296 | $6,711 | 841 | - | - | $95,326 | - | - | - | $35,562 697,296 kWh |
$6,711 841 kW-months/year |
- - MMBtu |
$95,326 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost |