Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2010 |
Principal Product | Disposable Thermometer Probe Covers and Light Bulbs |
NAICS | 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3845 - Electromedical Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 159,430 |
Annual Production | 390,000,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $354,944 | 4,741,865 | kWh | $0.07 |
Electricity Demand | $167,723 | 11,585 | kW-months/year | $14.48 |
Electricity Fees | $8,701 | - | $ | - |
Natural Gas | $76,275 | 10,193 | MMBtu | $7.48 |
TOTAL ENERGY COSTS | $607,643 | |||
RECOMMENDED SAVINGS* | $245,969 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $162,634 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Primary Raw Material | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $81,934 Cost: - |
$51,537 | 687,162 | $23,281 | 1,608 | - | - | $7,116 | 945 | - | - | - | - | - | - |
$51,537 687,162 kWh |
$23,281 1,608 kW-months/year |
- - $ |
$7,116 945 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,948 Cost: - |
$2,948 | 39,312 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,948 39,312 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,753 Cost: $554 |
$3,753 | 50,045 | - | - | - | - | - | - | - | - | - | - | - | - |
$3,753 50,045 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $758 Cost: $447 |
$758 | 10,101 | - | - | - | - | - | - | - | - | - | - | - | - |
$758 10,101 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $540 Cost: $793 |
$197 | 2,628 | $52 | 4 | - | - | - | - | $291 | - | - | - | - | - |
$197 2,628 kWh |
$52 4 kW-months/year |
- - $ |
- - MMBtu |
$291 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $79,942 Cost: $129,646 |
$2,948 | 39,312 | $3,127 | 216 | - | - | - | - | - | - | $73,867 | - | - | - |
$2,948 39,312 kWh |
$3,127 216 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$73,867 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $71,218 Cost: $132,133 |
$(-18,486) | (-246,480) | $(-6,863) | (-474) | - | - | - | - | - | - | - | - | $96,567 | - |
$(-18,486) (-246,480) kWh |
$(-6,863) (-474) kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
$96,567 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $373 Cost: $732 |
$373 | 4,976 | - | - | - | - | - | - | - | - | - | - | - | - |
$373 4,976 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,680 Cost: $5,928 |
$1,884 | 25,116 | $796 | 55 | - | - | - | - | - | - | - | - | - | - |
$1,884 25,116 kWh |
$796 55 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,823 Cost: $8,254 |
- | - | - | - | $1,823 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,823 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $245,969 Cost: $278,487 |
$45,912 | 612,172 | $20,393 | 1,409 | $1,823 | - | $7,116 | 945 | $291 | - | $73,867 | - | $96,567 | - | $45,912 612,172 kWh |
$20,393 1,409 kW-months/year |
$1,823 - $ |
$7,116 945 MMBtu |
$291 - $ |
$73,867 - $ |
$96,567 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $162,634 Cost: $130,093 |
$55,243 | 736,575 | $26,408 | 1,824 | - | - | $7,116 | 945 | - | - | $73,867 | - | - | - | $55,243 736,575 kWh |
$26,408 1,824 kW-months/year |
- - $ |
$7,116 945 MMBtu |
- - $ |
$73,867 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Primary Raw Material | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Primary Raw Material | Ancillary Material Cost |