Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2013 |
Principal Product | Medical Diagnostics Products |
NAICS | 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3845 - Electromedical Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 910 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $529,827 | 11,297,580 | kWh | $0.05 |
Electricity Demand | $301,845 | 25,379 | kW-months/year | $11.89 |
Electricity Fees | $12,689 | - | $ | - |
Natural Gas | $217,199 | 34,972 | MMBtu | $6.21 |
TOTAL ENERGY COSTS | $1,094,060 | |||
RECOMMENDED SAVINGS* | $71,432 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,510 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $10,408 Cost: - |
- | - | - | - | $10,408 | 1,676 | - | - |
- - kWh |
- - kW-months/year |
$10,408 1,676 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $8,049 Cost: - |
- | - | - | - | - | - | $8,049 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,049 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $1,239 Cost: - |
- | - | - | - | - | - | $1,239 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,239 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $30,158 Cost: $131 |
$30,158 | 641,555 | - | - | - | - | - | - |
$30,158 641,555 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $741 Cost: $191 |
$313 | 6,656 | $428 | 36 | - | - | - | - |
$313 6,656 kWh |
$428 36 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2123 INSULATE FEEDWATER TANK |
Savings: $579 Cost: $190 |
- | - | - | - | $579 | 93 | - | - |
- - kWh |
- - kW-months/year |
$579 93 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $579 Cost: $340 |
- | - | - | - | $579 | 93 | - | - |
- - kWh |
- - kW-months/year |
$579 93 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $18,624 Cost: $29,949 |
$(-88) | (-1,875) | $(-642) | (-54) | - | - | $19,354 | - |
$(-88) (-1,875) kWh |
$(-642) (-54) kW-months/year |
- - MMBtu |
$19,354 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $347 Cost: $771 |
$290 | 6,176 | $57 | 5 | - | - | - | - |
$290 6,176 kWh |
$57 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $298 Cost: $705 |
$(-53) | (-1,121) | $(-3) | (0) | $354 | 57 | - | - |
$(-53) (-1,121) kWh |
$(-3) (0) kW-months/year |
$354 57 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $221 Cost: $616 |
$221 | 4,693 | - | - | - | - | - | - |
$221 4,693 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $189 Cost: $852 |
$130 | 2,756 | $59 | 5 | - | - | - | - |
$130 2,756 kWh |
$59 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $71,432 Cost: $33,745 |
$30,971 | 658,840 | $(-101) | (-8) | $11,920 | 1,919 | $28,642 | - | $30,971 658,840 kWh |
$(-101) (-8) kW-months/year |
$11,920 1,919 MMBtu |
$28,642 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,510 Cost: $3,091 |
$31,112 | 661,836 | $544 | 46 | $11,566 | 1,862 | $9,288 | - | $31,112 661,836 kWh |
$544 46 kW-months/year |
$11,566 1,862 MMBtu |
$9,288 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |