Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2018 |
Principal Product | Wheat Flour |
NAICS | 311211 - Flour Milling |
SIC | 2041 - Flour And Other Grain Mill Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 540,000,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $622,408 | 26,269,300 | kWh | $0.02 |
Electricity Demand | $572,242 | 60,021 | kW-months/year | $9.53 |
Electricity Fees | $34,753 | - | $ | - |
Natural Gas | $59,941 | 13,066 | MMBtu | $4.59 |
TOTAL ENERGY COSTS | $1,289,344 | |||
RECOMMENDED SAVINGS* | $76,760 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $76,760 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $6,138 Cost: - |
- | - | - | - | - | - | - | - | - | - | $6,138 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$6,138 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $717 Cost: - |
$717 | 29,857 | - | - | - | - | - | - | - | - | - | - |
$717 29,857 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $150 Cost: - |
- | - | - | - | - | - | $150 | 33 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$150 33 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $28,600 Cost: $675 |
- | - | $28,600 | 3,001 | - | - | - | - | - | - | - | - |
- - kWh |
$28,600 3,001 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $5,417 Cost: $1,800 |
$(-22) | (-910) | $(-229) | (-24) | - | - | - | - | $1,300 | - | $4,368 | - |
$(-22) (-910) kWh |
$(-229) (-24) kW-months/year |
- - $ |
- - MMBtu |
$1,300 - $ |
$4,368 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $194 Cost: $125 |
$32 | 1,314 | $17 | 2 | - | - | - | - | $84 | - | $61 | - |
$32 1,314 kWh |
$17 2 kW-months/year |
- - $ |
- - MMBtu |
$84 - $ |
$61 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $27,797 Cost: $38,674 |
- | - | - | - | $27,797 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$27,797 - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $6,863 Cost: $15,312 |
$6,863 | 285,966 | - | - | - | - | - | - | - | - | - | - |
$6,863 285,966 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $884 Cost: $2,658 |
$799 | 33,288 | $440 | 46 | - | - | - | - | $17 | - | $(-372) | - |
$799 33,288 kWh |
$440 46 kW-months/year |
- - $ |
- - MMBtu |
$17 - $ |
$(-372) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,760 Cost: $59,244 |
$8,389 | 349,515 | $28,828 | 3,025 | $27,797 | - | $150 | 33 | $1,401 | - | $10,195 | - | $8,389 349,515 kWh |
$28,828 3,025 kW-months/year |
$27,797 - $ |
$150 33 MMBtu |
$1,401 - $ |
$10,195 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $76,760 Cost: $59,244 |
$8,389 | 349,515 | $28,828 | 3,025 | $27,797 | - | $150 | 33 | $1,401 | - | $10,195 | - | $8,389 349,515 kWh |
$28,828 3,025 kW-months/year |
$27,797 - $ |
$150 33 MMBtu |
$1,401 - $ |
$10,195 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |