Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2023 |
Principal Product | Industrial Laundry Equipment |
NAICS | 333310 - Commercial and Service Industry Machinery Manufacturing |
SIC | 3582 - Commercial Laundry Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 214 |
Plant Area (Sq.Ft.) | 255,000 |
Annual Production | 500 Units |
Production Hrs. Annual | 3,900 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $87,929 | 1,816,991 | kWh | $0.05 |
Electricity Demand | $76,768 | 6,526 | kW-months/year | $11.76 |
Electricity Fees | $12,478 | - | $ | - |
Natural Gas | $23,138 | 7,609 | MMBtu | $3.04 |
LPG | $11,752 | 134 | MMBtu | $87.90 |
TOTAL ENERGY COSTS | $212,065 | |||
RECOMMENDED SAVINGS* | $43,478 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7122 DISCONNECT BALLASTS |
Savings: $670 Cost: - |
$345 | 7,188 | $325 | 28 | - | - | - | - | - | - |
$345 7,188 kWh |
$325 28 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,834 Cost: - |
- | - | $3,834 | 326 | - | - | - | - | - | - |
- - kWh |
$3,834 326 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,775 Cost: $250 |
$1,224 | 25,500 | $882 | 75 | $(-331) | (-109) | - | - | - | - |
$1,224 25,500 kWh |
$882 75 kW-months/year |
$(-331) (-109) MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,688 Cost: $6,050 |
$3,688 | 76,837 | - | - | - | - | - | - | - | - |
$3,688 76,837 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $23,544 Cost: $39,388 |
$9,432 | 196,500 | $14,112 | 1,200 | - | - | - | - | - | - |
$9,432 196,500 kWh |
$14,112 1,200 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $158 Cost: $274 |
$158 | 3,295 | - | - | - | - | - | - | - | - |
$158 3,295 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,318 Cost: $2,488 |
$393 | 8,190 | $356 | 30 | - | - | - | - | $569 | - |
$393 8,190 kWh |
$356 30 kW-months/year |
- - MMBtu |
- - MMBtu |
$569 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $8,392 Cost: $24,000 |
$(-3,360) | (-70,000) | - | - | - | - | $11,752 | 134 | - | - |
$(-3,360) (-70,000) kWh |
- - kW-months/year |
- - MMBtu |
$11,752 134 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $99 Cost: $494 |
$99 | 2,052 | - | - | - | - | - | - | - | - |
$99 2,052 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,478 Cost: $72,944 |
$11,979 | 249,562 | $19,509 | 1,659 | $(-331) | (-109) | $11,752 | 134 | $569 | - | $11,979 249,562 kWh |
$19,509 1,659 kW-months/year |
$(-331) (-109) MMBtu |
$11,752 134 MMBtu |
$569 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | One-time Revenue or Avoided Cost |