Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2023
Principal Product Industrial Laundry Equipment
NAICS 333310 - Commercial and Service Industry Machinery Manufacturing
SIC 3582 - Commercial Laundry Equipment
Sales $10,000,000-$50,000,000
# of Employees 214
Plant Area (Sq.Ft.) 255,000
Annual Production 500 Units
Production Hrs. Annual 3,900
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $87,929 1,816,991 kWh $0.05
Electricity Demand $76,768 6,526 kW-months/year $11.76
Electricity Fees $12,478 - $ -
Natural Gas $23,138 7,609 MMBtu $3.04
LPG $11,752 134 MMBtu $87.90
TOTAL ENERGY COSTS $212,065
RECOMMENDED SAVINGS* $43,478 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas LPG One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas LPG One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
01: 2.7122 DISCONNECT BALLASTS Savings:
$670
Cost:
-
$345 7,188 $325 28 - - - - - - $345
7,188
kWh
$325
28
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$3,834
Cost:
-
- - $3,834 326 - - - - - - -
-
kWh
$3,834
326
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$1,775
Cost:
$250
$1,224 25,500 $882 75 $(-331) (-109) - - - - $1,224
25,500
kWh
$882
75
kW-months/year
$(-331)
(-109)
MMBtu
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,688
Cost:
$6,050
$3,688 76,837 - - - - - - - - $3,688
76,837
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$23,544
Cost:
$39,388
$9,432 196,500 $14,112 1,200 - - - - - - $9,432
196,500
kWh
$14,112
1,200
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$158
Cost:
$274
$158 3,295 - - - - - - - - $158
3,295
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,318
Cost:
$2,488
$393 8,190 $356 30 - - - - $569 - $393
8,190
kWh
$356
30
kW-months/year
-
-
MMBtu
-
-
MMBtu
$569
-
$
08: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$8,392
Cost:
$24,000
$(-3,360) (-70,000) - - - - $11,752 134 - - $(-3,360)
(-70,000)
kWh
-
-
kW-months/year
-
-
MMBtu
$11,752
134
MMBtu
-
-
$
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$99
Cost:
$494
$99 2,052 - - - - - - - - $99
2,052
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$43,478
Cost:
$72,944
$11,979 249,562 $19,509 1,659 $(-331) (-109) $11,752 134 $569 - $11,979
249,562
kWh
$19,509
1,659
kW-months/year
$(-331)
(-109)
MMBtu
$11,752
134
MMBtu
$569
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas LPG One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas LPG One-time Revenue or Avoided Cost