IAC logo
IAC Assessment: SU0562
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0562
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2024
Principal Product Electronic Circuit Boards
NAICS 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3672 - Printed Circuit Boards
Sales $10,000,000-$50,000,000
# of Employees 95
Plant Area (Sq.Ft.) 32,000
Annual Production 400,000 Units
Production Hrs. Annual 2,080
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $53,097 643,400 kWh $0.08
Electricity Demand $41,797 3,150 kW-months/year $13.27
Electricity Fees $4,219 - $ -
Natural Gas $5,001 584 MMBtu $8.56
Other Gas $506 1 MMBtu $505.87
TOTAL ENERGY COSTS $104,619
RECOMMENDED SAVINGS* $144,966 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.7122 DISCONNECT BALLASTS Savings:
$526
Cost:
-
$273 3,295 $252 19 - - - - - - $273
3,295
kWh
$252
19
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,090
Cost:
-
- - $2,090 158 - - - - - - -
-
kWh
$2,090
158
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$656
Cost:
-
$656 7,898 - - - - - - - - $656
7,898
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$3,064
Cost:
$120
- - - - - - - - $3,064 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$3,064
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$374
Cost:
$418
- - - - $374 44 - - - - -
-
kWh
-
-
kW-months/year
$374
44
MMBtu
-
-
$
-
-
$
06: 4.651 INSTALL BACK-UP EQUIPMENT Savings:
$75,000
Cost:
$86,000
- - - - - - $75,000 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$75,000
-
$
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$419
Cost:
$632
$419 5,052 - - - - - - - - $419
5,052
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
08: 4.631 INSTALL AN UNINTERUPTABLE POWER SUPPLY Savings:
$25,000
Cost:
$80,000
- - - - - - - - $25,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$25,000
-
$
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$639
Cost:
$2,272
$986 11,876 - - $(-347) (-41) - - - - $986
11,876
kWh
-
-
kW-months/year
$(-347)
(-41)
MMBtu
-
-
$
-
-
$
10: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$291
Cost:
$1,234
$291 3,504 - - - - - - - - $291
3,504
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
11: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS Savings:
$437
Cost:
$2,900
$437 5,265 - - - - - - - - $437
5,265
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
12: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$36,470
Cost:
$266,289
$36,470 439,398 - - - - - - - - $36,470
439,398
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$144,966
Cost:
$439,865
$39,532 476,288 $2,342 177 $28 3 $75,000 - $28,064 - $39,532
476,288
kWh
$2,342
177
kW-months/year
$28
3
MMBtu
$75,000
-
$
$28,064
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Administrative Changes One-time Revenue or Avoided Cost