IAC logo
IAC Assessment: SU0572
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: SU0572
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Syracuse University
Assessment Year 2025
Principal Product Notepads, Sewing Operation
NAICS 339999 - All Other Miscellaneous Manufacturing
SIC 8331 - Job Training And Related Services
Sales $10,000,000-$50,000,000
# of Employees 141
Plant Area (Sq.Ft.) 75,000
Annual Production 825,553 Units
Production Hrs. Annual 2,860
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $57,034 730,426 kWh $0.08
Electricity Demand $51,659 2,508 kW-months/year $20.60
Electricity Fees $17,848 - $ -
Natural Gas $16,768 2,821 MMBtu $5.94
Other Gas $209 1 MMBtu $208.97
Other Energy $2,344 1 MMBtu $2,344.44
TOTAL ENERGY COSTS $145,863
RECOMMENDED SAVINGS* $47,252 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$1,783
Cost:
-
$1,115 14,300 $1,030 50 $(-362) (-61) - - $1,115
14,300
kWh
$1,030
50
kW-months/year
$(-362)
(-61)
MMBtu
-
-
$
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$4,651
Cost:
-
- - - - $4,651 783 - - -
-
kWh
-
-
kW-months/year
$4,651
783
MMBtu
-
-
$
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,576
Cost:
-
- - $2,576 125 - - - - -
-
kWh
$2,576
125
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$144
Cost:
-
$144 1,835 - - - - - - $144
1,835
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$2,035
Cost:
$65
- - - - - - $2,035 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$2,035
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$813
Cost:
$771
- - - - $813 137 - - -
-
kWh
-
-
kW-months/year
$813
137
MMBtu
-
-
$
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$673
Cost:
$691
$355 4,555 $129 6 - - $189 - $355
4,555
kWh
$129
6
kW-months/year
-
-
MMBtu
$189
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,746
Cost:
$5,006
$1,651 21,164 $1,829 89 - - $1,266 - $1,651
21,164
kWh
$1,829
89
kW-months/year
-
-
MMBtu
$1,266
-
$
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$167
Cost:
$359
$167 2,146 - - - - - - $167
2,146
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
10: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$29,664
Cost:
$180,240
$29,664 380,312 - - - - - - $29,664
380,312
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$47,252
Cost:
$187,132
$33,097 424,312 $5,564 270 $5,102 858 $3,489 - $33,097
424,312
kWh
$5,564
270
kW-months/year
$5,102
858
MMBtu
$3,489
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost