Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Syracuse University |
---|---|
Assessment Year | 2025 |
Principal Product | Wood Office Furniture |
NAICS | 337211 - Wood Office Furniture Manufacturing |
SIC | 2521 - Wood Office Furniture |
Sales | $100,000,000-$500,000,000 |
# of Employees | 144 |
Plant Area (Sq.Ft.) | 750,000 |
Annual Production | 104,107 Units |
Production Hrs. Annual | 2,000 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $409,833 | 7,156,373 | kWh | $0.06 |
Electricity Demand | $151,240 | 38,620 | kW-months/year | $3.92 |
Electricity Fees | $34,159 | - | $ | - |
Natural Gas | $292,828 | 65,251 | MMBtu | $4.49 |
LPG | $1,555 | 46 | MMBtu | $33.74 |
Other Gas | $58,821 | 65,251 | MMBtu | $0.90 |
TOTAL ENERGY COSTS | $948,437 | |||
RECOMMENDED SAVINGS* | $119,150 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $15,025 Cost: - |
- | - | - | - | - | - | $15,025 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$15,025 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $7,562 Cost: - |
- | - | $7,562 | 1,931 | - | - | - | - |
- - kWh |
$7,562 1,931 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $500 Cost: - |
$447 | 7,840 | $53 | 13 | - | - | - | - |
$447 7,840 kWh |
$53 13 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $442 Cost: - |
$50 | 876 | $392 | 100 | - | - | - | - |
$50 876 kWh |
$392 100 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $951 Cost: - |
$951 | 16,684 | - | - | - | - | - | - |
$951 16,684 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $9,354 Cost: $420 |
$1,207 | 21,167 | - | - | $8,147 | 1,815 | - | - |
$1,207 21,167 kWh |
- - kW-months/year |
$8,147 1,815 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $874 Cost: $58 |
$821 | 14,400 | $329 | 84 | $(-276) | (-61) | - | - |
$821 14,400 kWh |
$329 84 kW-months/year |
$(-276) (-61) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $525 Cost: $107 |
$525 | 9,208 | - | - | - | - | - | - |
$525 9,208 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7314 REDUCE VENTILATION AIR |
Savings: $1,135 Cost: $499 |
$506 | 8,871 | - | - | $629 | 140 | - | - |
$506 8,871 kWh |
- - kW-months/year |
$629 140 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,324 Cost: $2,320 |
$5,242 | 91,968 | $82 | 21 | - | - | - | - |
$5,242 91,968 kWh |
$82 21 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,627 Cost: $14,880 |
$11,041 | 193,704 | $4,551 | 1,162 | - | - | $1,034 | - |
$11,041 193,704 kWh |
$4,551 1,162 kW-months/year |
- - MMBtu |
$1,034 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $53,073 Cost: $79,597 |
$53,073 | 931,101 | - | - | - | - | - | - |
$53,073 931,101 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $294 Cost: $445 |
- | - | - | - | $294 | 55 | - | - |
- - kWh |
- - kW-months/year |
$294 55 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,331 Cost: $2,080 |
$634 | 11,125 | $60 | 15 | - | - | $637 | - |
$634 11,125 kWh |
$60 15 kW-months/year |
- - MMBtu |
$637 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $350 Cost: $745 |
$350 | 6,132 | - | - | - | - | - | - |
$350 6,132 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $574 Cost: $1,355 |
$574 | 10,067 | - | - | - | - | - | - |
$574 10,067 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,185 Cost: $2,822 |
- | - | - | - | $1,185 | 264 | - | - |
- - kWh |
- - kW-months/year |
$1,185 264 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $4,025 Cost: $15,784 |
- | - | - | - | $4,025 | 896 | - | - |
- - kWh |
- - kW-months/year |
$4,025 896 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $119,150 Cost: $121,112 |
$75,420 | 1,323,144 | $13,028 | 3,327 | $14,005 | 3,109 | $16,697 | - | $75,420 1,323,144 kWh |
$13,028 3,327 kW-months/year |
$14,005 3,109 MMBtu |
$16,697 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||