Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas, Arlington |
---|---|
Assessment Year | 2003 |
Principal Product | Custom Motorcycles |
NAICS | 336991 - Motorcycle, Bicycle, and Parts Manufacturing |
SIC | 3751 - Motorcycles, Bicycles, And Parts |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 1,600 Pieces |
Production Hrs. Annual | 6,072 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $78,456 | 1,713,300 | kWh | $0.05 |
Electricity Demand | $32,398 | 4,156 | kW-months/year | $7.80 |
Electricity Fees | $3,904 | - | $ | - |
Natural Gas | $19,956 | 3,996 | MMBtu | $4.99 |
TOTAL ENERGY COSTS | $184,714 | |||
RECOMMENDED SAVINGS* | $35,845 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $27,670 Cost: $800 |
- | - | - | - | $25,000 | 50,000 | $(-2,530) | - | $5,200 | - | - | - |
- - kWh |
- - kW-months/year |
$25,000 50,000 Tgal |
$(-2,530) - $ |
$5,200 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,140 Cost: $200 |
$1,830 | 55,700 | $1,310 | 110 | - | - | - | - | - | - | - | - |
$1,830 55,700 kWh |
$1,310 110 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $1,990 Cost: - |
- | - | - | - | - | - | - | - | - | - | $1,990 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
$1,990 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,740 Cost: $3,230 |
$680 | 20,687 | $1,060 | 89 | - | - | - | - | - | - | - | - |
$680 20,687 kWh |
$1,060 89 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $370 Cost: - |
$370 | 11,510 | - | - | - | - | - | - | - | - | - | - |
$370 11,510 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $520 Cost: $145 |
$190 | 5,885 | $330 | 12 | - | - | - | - | - | - | - | - |
$190 5,885 kWh |
$330 12 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $215 Cost: $445 |
$145 | 4,415 | $70 | 6 | - | - | - | - | - | - | - | - |
$145 4,415 kWh |
$70 6 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $200 Cost: - |
$200 | 6,135 | - | - | - | - | - | - | - | - | - | - |
$200 6,135 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,845 Cost: $4,820 |
$3,415 | 104,332 | $2,770 | 217 | $25,000 | 50,000 | $(-2,530) | - | $5,200 | - | $1,990 | - | $3,415 104,332 kWh |
$2,770 217 kW-months/year |
$25,000 50,000 Tgal |
$(-2,530) - $ |
$5,200 - $ |
$1,990 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,125 Cost: $4,675 |
$3,025 | 92,312 | $2,440 | 205 | $25,000 | 50,000 | $(-2,530) | - | $5,200 | - | $1,990 | - | $3,025 92,312 kWh |
$2,440 205 kW-months/year |
$25,000 50,000 Tgal |
$(-2,530) - $ |
$5,200 - $ |
$1,990 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material |