Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas, Arlington |
---|---|
Assessment Year | 2003 |
Principal Product | Refigeration and Heating Equipment |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 195,000 |
Annual Production | 1,068,365 Pieces |
Production Hrs. Annual | 3,544 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $300,202 | 6,465,588 | kWh | $0.05 |
Electricity Demand | $16,089 | 7,806 | kW-months/year | $2.06 |
Electricity Fees | $31,502 | - | $ | - |
Natural Gas | $109,839 | 17,176 | MMBtu | $6.39 |
TOTAL ENERGY COSTS | $457,632 | |||
RECOMMENDED SAVINGS* | $173,707 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $53,018 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $116,629 Cost: $26,800 |
$53,818 | 1,240,037 | - | - | - | - | $62,811 | 9,822 |
$53,818 1,240,037 kWh |
- - kW-months/year |
- - $ |
$62,811 9,822 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $14,100 Cost: - |
$14,100 | 325,200 | - | - | - | - | - | - |
$14,100 325,200 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $11,288 Cost: - |
- | - | - | - | $11,288 | - | - | - |
- - kWh |
- - kW-months/year |
$11,288 - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,890 Cost: $620 |
$5,920 | 136,320 | $970 | 203 | - | - | - | - |
$5,920 136,320 kWh |
$970 203 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,290 Cost: $1,200 |
$5,470 | 126,120 | $820 | 172 | - | - | - | - |
$5,470 126,120 kWh |
$820 172 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,510 Cost: $430 |
$2,560 | 59,000 | $950 | 200 | - | - | - | - |
$2,560 59,000 kWh |
$950 200 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,810 Cost: $605 |
$1,290 | 29,736 | - | - | - | - | $2,520 | 295 |
$1,290 29,736 kWh |
- - kW-months/year |
- - $ |
$2,520 295 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,310 Cost: - |
- | - | - | - | - | - | $2,310 | 361 |
- - kWh |
- - kW-months/year |
- - $ |
$2,310 361 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,030 Cost: - |
$1,480 | 34,020 | $550 | 115 | - | - | - | - |
$1,480 34,020 kWh |
$550 115 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,270 Cost: - |
$2,270 | 52,200 | - | - | - | - | - | - |
$2,270 52,200 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,500 Cost: - |
$1,500 | 34,490 | - | - | - | - | - | - |
$1,500 34,490 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,050 Cost: $406 |
$1,050 | 24,195 | - | - | - | - | - | - |
$1,050 24,195 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $895 Cost: $225 |
- | - | - | - | - | - | $895 | 140 |
- - kWh |
- - kW-months/year |
- - $ |
$895 140 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $610 Cost: $180 |
$440 | 10,290 | $170 | 35 | - | - | - | - |
$440 10,290 kWh |
$170 35 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $330 Cost: $120 |
- | - | - | - | - | - | $330 | 51 |
- - kWh |
- - kW-months/year |
- - $ |
$330 51 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $195 Cost: $120 |
$170 | 3,925 | $25 | 5 | - | - | - | - |
$170 3,925 kWh |
$25 5 kW-months/year |
- - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,707 Cost: $30,706 |
$90,068 | 2,075,533 | $3,485 | 730 | $11,288 | - | $68,866 | 10,669 | $90,068 2,075,533 kWh |
$3,485 730 kW-months/year |
$11,288 - $ |
$68,866 10,669 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $53,018 Cost: $3,261 |
$34,160 | 787,261 | $2,740 | 575 | $11,288 | - | $4,830 | 656 | $34,160 787,261 kWh |
$2,740 575 kW-months/year |
$11,288 - $ |
$4,830 656 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas |