Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas, Arlington |
---|---|
Assessment Year | 2004 |
Principal Product | Electronic Connectors |
NAICS | 334417 - Electronic Connector Manufacturing |
SIC | 3678 - Electronic Connectors |
Sales | $10,000,000-$50,000,000 |
# of Employees | 186 |
Plant Area (Sq.Ft.) | 32,600 |
Annual Production | 51,000,000 Pieces |
Production Hrs. Annual | 5,560 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $235,959 | 4,574,626 | kWh | $0.05 |
Electricity Demand | $84,902 | 18,365 | kW-months/year | $4.62 |
TOTAL ENERGY COSTS | $320,861 | |||
RECOMMENDED SAVINGS* | $76,523 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,391 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $36,101 Cost: $25,800 |
$36,101 | 500,500 | - | - | - | - | - | - | - | - | - | - |
$36,101 500,500 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $21,003 Cost: $12,967 |
$17,758 | 245,581 | $3,245 | 628 | - | - | - | - | - | - | - | - |
$17,758 245,581 kWh |
$3,245 628 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $10,113 Cost: - |
- | - | - | - | $10,113 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,113 - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,277 Cost: - |
$3,277 | 63,274 | - | - | - | - | - | - | - | - | - | - |
$3,277 63,274 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,001 Cost: $720 |
$2,603 | 36,086 | $398 | 77 | - | - | - | - | - | - | - | - |
$2,603 36,086 kWh |
$398 77 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $1,680 Cost: $732 |
$1,473 | 20,419 | $207 | 44 | - | - | - | - | - | - | - | - |
$1,473 20,419 kWh |
$207 44 kW-months/year |
- - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $880 Cost: - |
- | - | - | - | - | - | $550 | 25 | - | - | $330 | - |
- - kWh |
- - kW-months/year |
- - $ |
$550 25 Tgal |
- - gal |
$330 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $468 Cost: - |
- | - | - | - | - | - | - | - | $468 | 312 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$468 312 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,523 Cost: $40,219 |
$61,212 | 865,860 | $3,850 | 749 | $10,113 | - | $550 | 25 | $468 | 312 | $330 | - | $61,212 865,860 kWh |
$3,850 749 kW-months/year |
$10,113 - $ |
$550 25 Tgal |
$468 312 gal |
$330 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,391 Cost: $720 |
$5,880 | 99,360 | $398 | 77 | $10,113 | - | - | - | - | - | - | - | $5,880 99,360 kWh |
$398 77 kW-months/year |
$10,113 - $ |
- - Tgal |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Other Liquid (non-haz) | Personnel Changes |