IAC logo
IAC Assessment: TA0094
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TA0094
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Texas, Arlington
Assessment Year 2005
Principal Product Wheat Flour
NAICS 311211 - Flour Milling
SIC 2041 - Flour And Other Grain Mill Products
Sales $50,000,000-$100,000,000
# of Employees 120
Plant Area (Sq.Ft.) 800,000
Annual Production 781,000,000 Pounds
Production Hrs. Annual 8,520
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,351,989 28,631,474 kWh $0.05
Electricity Demand $261,379 52,910 kW-months/year $4.94
TOTAL ENERGY COSTS $1,613,368
RECOMMENDED SAVINGS* $12,950 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,810
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,225
Cost:
$410
$5,700 120,760 $525 170 $5,700
120,760
kWh
$525
170
kW-months/year
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$4,585
Cost:
$125
$4,200 88,980 $385 125 $4,200
88,980
kWh
$385
125
kW-months/year
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,640
Cost:
-
$1,500 31,900 $140 45 $1,500
31,900
kWh
$140
45
kW-months/year
04: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$325
Cost:
-
$265 5,606 $60 19 $265
5,606
kWh
$60
19
kW-months/year
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$175
Cost:
-
$175 3,700 - - $175
3,700
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$12,950
Cost:
$535
$11,840 250,946 $1,110 359 $11,840
250,946
kWh
$1,110
359
kW-months/year
TOTAL IMPLEMENTED Savings:
$10,810
Cost:
$535
$9,900 209,740 $910 295 $9,900
209,740
kWh
$910
295
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand