Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas, Arlington |
---|---|
Assessment Year | 2005 |
Principal Product | Metal Storage Racks |
NAICS | 337215 - Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 2542 - Partitions And Fixtures, Except Wood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 280,000 |
Annual Production | 11,000 Pieces |
Production Hrs. Annual | 5,572 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $229,364 | 4,063,930 | kWh | $0.06 |
Electricity Demand | $77,114 | 10,601 | kW-months/year | $7.27 |
Natural Gas | $478,026 | 42,261 | MMBtu | $11.31 |
TOTAL ENERGY COSTS | $784,504 | |||
RECOMMENDED SAVINGS* | $34,410 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,498 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8118 CHECK FOR ACCURACY OF UTILITY / POWER METERS |
Savings: $8,253 Cost: - |
- | - | - | - | $8,253 | - | - | - |
- - kWh |
- - kW-months/year |
$8,253 - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $6,829 Cost: $176 |
$5,794 | 98,722 | $1,035 | 179 | - | - | - | - |
$5,794 98,722 kWh |
$1,035 179 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,341 Cost: $1,038 |
$5,237 | 89,239 | $1,104 | 191 | - | - | - | - |
$5,237 89,239 kWh |
$1,104 191 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,277 Cost: - |
$5,179 | 88,260 | $1,098 | 190 | - | - | - | - |
$5,179 88,260 kWh |
$1,098 190 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,486 Cost: $270 |
$2,486 | 42,365 | - | - | - | - | - | - |
$2,486 42,365 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7312 IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS |
Savings: $2,320 Cost: $50 |
- | - | - | - | - | - | $2,320 | 1,303 |
- - kWh |
- - kW-months/year |
- - $ |
$2,320 1,303 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $1,904 Cost: - |
$610 | 10,392 | $1,294 | 223 | - | - | - | - |
$610 10,392 kWh |
$1,294 223 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,410 Cost: $1,534 |
$19,306 | 328,978 | $4,531 | 783 | $8,253 | - | $2,320 | 1,303 | $19,306 328,978 kWh |
$4,531 783 kW-months/year |
$8,253 - $ |
$2,320 1,303 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,498 Cost: $1,038 |
$5,847 | 99,631 | $2,398 | 414 | $8,253 | - | - | - | $5,847 99,631 kWh |
$2,398 414 kW-months/year |
$8,253 - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) |