IAC logo
IAC Assessment: TA0113
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: TA0113
IAC Center University of Texas, Arlington
Assessment Year 2006
Principal Product Misc. Sheet Metal Work
NAICS 332322 - Sheet Metal Work Manufacturing
SIC 3444 - Sheet Metalwork
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 210,000
Annual Production 56,250 Units
Production Hrs. Annual 4,000
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $210,014 2,392,077 kWh $0.09
Electricity Demand $45,216 8,040 kW-months/year $5.62
Natural Gas $4,631 545 MMBtu $8.50
TOTAL ENERGY COSTS $259,861
RECOMMENDED SAVINGS* $80,667 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $67,742
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$55,045
Cost:
$24,738
$48,806 351,120 $6,239 1,054 $48,806
351,120
kWh
$6,239
1,054
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$540
Cost:
$370
$510 3,669 $30 5 $510
3,669
kWh
$30
5
kW-months/year
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$12,153
Cost:
$1,123
$12,153 87,430 - - $12,153
87,430
kWh
-
-
kW-months/year
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$232
Cost:
$340
$185 1,326 $47 8 $185
1,326
kWh
$47
8
kW-months/year
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$12,697
Cost:
$25,000
- - $12,697 2,144 -
-
kWh
$12,697
2,144
kW-months/year
TOTAL RECOMMENDED Savings:
$80,667
Cost:
$51,571
$61,654 443,545 $19,013 3,211 $61,654
443,545
kWh
$19,013
3,211
kW-months/year
TOTAL IMPLEMENTED Savings:
$67,742
Cost:
$49,738
$48,806 351,120 $18,936 3,198 $48,806
351,120
kWh
$18,936
3,198
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand