Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Texas, Arlington
Assessment Year 2006
Principal Product bottled and canned soft drinks
NAICS 312111 - Soft Drink Manufacturing
SIC 2086 - Bottled And Canned Soft Drinks
Sales $100,000,000-$500,000,000
# of Employees 600
Plant Area (Sq.Ft.) 170,400
Annual Production 3,500,000 Pieces
Production Hrs. Annual 5,712
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,353,923 14,883,394 kWh $0.09
Electricity Demand $186,426 27,545 kW-months/year $6.77
Natural Gas $35,371 40,412 MMBtu $0.88
TOTAL ENERGY COSTS $1,575,720
RECOMMENDED SAVINGS* $28,068 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $28,068
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$17,192
Cost:
-
$15,561 154,224 $1,631 324 - - - - $15,561
154,224
kWh
$1,631
324
kW-months/year
-
-
$
-
-
MMBtu
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$81
Cost:
$252
- - - - - - $81 93 -
-
kWh
-
-
kW-months/year
-
-
$
$81
93
MMBtu
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,795
Cost:
$22,000
- - - - $10,795 - - - -
-
kWh
-
-
kW-months/year
$10,795
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$28,068
Cost:
$22,252
$15,561 154,224 $1,631 324 $10,795 - $81 93 $15,561
154,224
kWh
$1,631
324
kW-months/year
$10,795
-
$
$81
93
MMBtu
TOTAL IMPLEMENTED Savings:
$28,068
Cost:
$22,252
$15,561 154,224 $1,631 324 $10,795 - $81 93 $15,561
154,224
kWh
$1,631
324
kW-months/year
$10,795
-
$
$81
93
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas