Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1989 |
Principal Product | HOSPITAL STOCKINGS |
NAICS | n/a |
SIC | 3842 - Surgical Appliances And Supplies |
Sales | $10,000,000-$50,000,000 |
# of Employees | 420 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 570,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $454,187 | 8,754,689 | kWh | $0.05 |
Natural Gas | $47,453 | 18,373 | MMBtu | $2.58 |
Fuel Oil #6 | $37,974 | 15,171 | MMBtu | $2.50 |
TOTAL ENERGY COSTS | $539,614 | |||
RECOMMENDED SAVINGS* | $39,343 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,359 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE |
Savings: $4,924 Cost: - |
- | - | $2,756 | 1,060 | $2,168 | 867 | - | - |
- - kWh |
$2,756 1,060 MMBtu |
$2,168 867 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $4,213 Cost: $720 |
- | - | $2,358 | 907 | $1,855 | 742 | - | - |
- - kWh |
$2,358 907 MMBtu |
$1,855 742 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,450 Cost: $718 |
- | - | $1,370 | 527 | $1,080 | 432 | - | - |
- - kWh |
$1,370 527 MMBtu |
$1,080 432 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN |
Savings: $10,766 Cost: $33,188 |
$10,363 | 199,297 | - | - | - | - | $403 | - |
$10,363 199,297 kWh |
- - MMBtu |
- - MMBtu |
$403 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $1,712 Cost: $4,156 |
- | - | $954 | 367 | $758 | 303 | - | - |
- - kWh |
$954 367 MMBtu |
$758 303 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,977 Cost: $330 |
$8,977 | 172,626 | - | - | - | - | - | - |
$8,977 172,626 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $959 Cost: $1,960 |
- | - | $536 | 206 | $423 | 169 | - | - |
- - kWh |
$536 206 MMBtu |
$423 169 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $556 Cost: - |
- | - | $479 | 184 | $377 | 151 | $(-300) | - |
- - kWh |
$479 184 MMBtu |
$377 151 MMBtu |
$(-300) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,404 Cost: $4,000 |
$4,404 | 84,701 | - | - | - | - | - | - |
$4,404 84,701 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $123 Cost: $50 |
- | - | $68 | 26 | $55 | 22 | - | - |
- - kWh |
$68 26 MMBtu |
$55 22 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $259 Cost: $270 |
$259 | 4,982 | - | - | - | - | - | - |
$259 4,982 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,343 Cost: $45,392 |
$24,003 | 461,606 | $8,521 | 3,277 | $6,716 | 2,686 | $103 | - | $24,003 461,606 kWh |
$8,521 3,277 MMBtu |
$6,716 2,686 MMBtu |
$103 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,359 Cost: $9,974 |
$13,381 | 257,327 | $7,985 | 3,071 | $6,293 | 2,517 | $(-300) | - | $13,381 257,327 kWh |
$7,985 3,071 MMBtu |
$6,293 2,517 MMBtu |
$(-300) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes |