Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1990 |
Principal Product | PENCIL LEADS |
NAICS | n/a |
SIC | 3952 - Lead Pencils And Art Goods |
Sales | $1,000,000-$5,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 1,800,000 Pieces |
Production Hrs. Annual | 0 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $124,356 | 2,250,586 | kWh | $0.06 |
Natural Gas | $22,467 | 4,515 | MMBtu | $4.98 |
Fuel Oil #2 | $32,398 | 7,039 | MMBtu | $4.60 |
TOTAL ENERGY COSTS | $179,221 | |||
RECOMMENDED SAVINGS* | $14,162 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,484 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Fuel Oil #2 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #2 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2162 REDUCE EXCESS STEAM BLEEDING |
Savings: $5,335 Cost: $1,280 |
- | - | $2,085 | 417 | $3,250 | 711 | - | - |
- - kWh |
$2,085 417 MMBtu |
$3,250 711 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,167 Cost: $2,442 |
- | - | $3,865 | 773 | $302 | 66 | - | - |
- - kWh |
$3,865 773 MMBtu |
$302 66 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $1,886 Cost: $4,964 |
$1,886 | 34,291 | - | - | - | - | - | - |
$1,886 34,291 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $501 Cost: $356 |
- | - | $195 | 39 | $306 | 67 | - | - |
- - kWh |
$195 39 MMBtu |
$306 67 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $213 Cost: $300 |
- | - | $85 | 17 | $128 | 28 | - | - |
- - kWh |
$85 17 MMBtu |
$128 28 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $532 Cost: - |
$532 | 9,672 | - | - | - | - | - | - |
$532 9,672 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $742 Cost: $236 |
$742 | 13,482 | - | - | - | - | - | - |
$742 13,482 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $322 Cost: $180 |
$322 | 5,862 | - | - | - | - | - | - |
$322 5,862 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7123 KEEP LAMPS AND REFLECTORS CLEAN |
Savings: $303 Cost: $963 |
$274 | 4,982 | - | - | - | - | $29 | - |
$274 4,982 kWh |
- - MMBtu |
- - MMBtu |
$29 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $161 Cost: $90 |
$161 | 2,931 | - | - | - | - | - | - |
$161 2,931 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,162 Cost: $10,811 |
$3,917 | 71,220 | $6,230 | 1,246 | $3,986 | 872 | $29 | - | $3,917 71,220 kWh |
$6,230 1,246 MMBtu |
$3,986 872 MMBtu |
$29 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,484 Cost: $2,262 |
$1,435 | 26,085 | $2,365 | 473 | $3,684 | 806 | - | - | $1,435 26,085 kWh |
$2,365 473 MMBtu |
$3,684 806 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Fuel Oil #2 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #2 | Administrative Changes |