IAC logo
IAC Assessment: TN0441
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TN0441
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Tennessee
Assessment Year 1991
Principal Product BLANKETS, BEDSPREADS
NAICS n/a
SIC 2392 - Housefurnishings, Nec
Sales $50,000,000-$100,000,000
# of Employees 650
Plant Area (Sq.Ft.) 0
Annual Production 12,120,000 Pieces
Production Hrs. Annual 8,232
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,029,949 22,050,118 kWh $0.05
Natural Gas $225,315 49,675 MMBtu $4.54
Coal $200,751 143,220 MMBtu $1.40
TOTAL ENERGY COSTS $1,456,015
RECOMMENDED SAVINGS* $56,284 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Coal Administrative Changes Electricity Usage Coal Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$5,308
Cost:
$2,090
- - $5,308 3,811 - - -
-
kWh
$5,308
3,811
MMBtu
-
-
$
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,631
Cost:
$770
- - $1,631 1,171 - - -
-
kWh
$1,631
1,171
MMBtu
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$13,017
Cost:
-
$13,017 276,964 - - - - $13,017
276,964
kWh
-
-
MMBtu
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,295
Cost:
$2,396
- - $1,295 930 - - -
-
kWh
$1,295
930
MMBtu
-
-
$
05: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,013
Cost:
$100
- - $1,013 727 - - -
-
kWh
$1,013
727
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$5,813
Cost:
$1,440
$5,813 123,681 - - - - $5,813
123,681
kWh
-
-
MMBtu
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,746
Cost:
-
$8,430 179,367 - - $(-1,684) - $8,430
179,367
kWh
-
-
MMBtu
$(-1,684)
-
$
08: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,708
Cost:
-
$1,708 36,342 - - - - $1,708
36,342
kWh
-
-
MMBtu
-
-
$
09: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$19,753
Cost:
$20,800
$19,753 - - - - - $19,753
-
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$56,284
Cost:
$27,596
$48,721 616,354 $9,247 6,639 $(-1,684) - $48,721
616,354
kWh
$9,247
6,639
MMBtu
$(-1,684)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Coal Administrative Changes Electricity Usage Coal Administrative Changes