Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 1997 |
Principal Product | Carpentry tools |
NAICS | n/a |
SIC | 3423 - Hand And Edge Tools, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 106 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 2,000,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $52,664 | 1,548,945 | kWh | $0.03 |
Electricity Demand | $39,773 | 5,631 | kW-months/year | $7.06 |
Electricity Fees | $1,748 | - | $ | - |
Natural Gas | $74,619 | 10,479 | MMBtu | $7.12 |
TOTAL ENERGY COSTS | $300,076 | |||
RECOMMENDED SAVINGS* | $27,700 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,005 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $13,200 Cost: - |
- | - | - | - | - | - | - | - | $(-45,000) | - | - | - | $58,200 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$(-45,000) - $ |
- - $ |
$58,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $4,865 Cost: $8,000 |
- | - | - | - | - | - | $4,865 | 10,040 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,865 10,040 lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,270 Cost: - |
- | - | - | - | - | - | $3,270 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,270 - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,960 Cost: $295 |
$2,960 | 95,545 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,960 95,545 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,045 Cost: - |
$430 | 13,775 | $1,565 | 192 | - | - | - | - | - | - | $50 | - | - | - |
$430 13,775 kWh |
$1,565 192 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$50 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7122 DISCONNECT BALLASTS |
Savings: $1,190 Cost: $180 |
$700 | 22,567 | $490 | 60 | - | - | - | - | - | - | - | - | - | - |
$700 22,567 kWh |
$490 60 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $170 Cost: $180 |
- | - | - | - | $170 | 24 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$170 24 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,700 Cost: $8,655 |
$4,090 | 131,887 | $2,055 | 252 | $170 | 24 | $8,135 | 10,040 | $(-45,000) | - | $50 | - | $58,200 | - | $4,090 131,887 kWh |
$2,055 252 kW-months/year |
$170 24 MMBtu |
$8,135 10,040 lb |
$(-45,000) - $ |
$50 - $ |
$58,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,005 Cost: $295 |
$3,390 | 109,320 | $1,565 | 192 | - | - | - | - | - | - | $50 | - | - | - | $3,390 109,320 kWh |
$1,565 192 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$50 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Primary Product |