Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 2000 |
Principal Product | Hardwood Flooring |
NAICS | n/a |
SIC | 2426 - Hardwood Dimension & Flooring Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 15,000 Thousand Feet |
Production Hrs. Annual | 4,000 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $149,725 | 4,422,919 | kWh | $0.03 |
Electricity Demand | $75,158 | 12,526 | kW-months/year | $6.00 |
Electricity Fees | $9,373 | - | $ | - |
TOTAL ENERGY COSTS | $234,256 | |||
RECOMMENDED SAVINGS* | $154,858 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,310 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $75,400 Cost: $400,000 |
- | - | - | - | - | - | $75,400 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$75,400 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $37,500 Cost: $16,430 |
- | - | - | - | - | - | - | - | $37,500 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$37,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $30,832 Cost: $1,075 |
$3,832 | 61,254 | - | - | - | - | - | - | $27,000 | - |
$3,832 61,254 kWh |
- - kW-months/year |
- - lb |
- - $ |
$27,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,356 Cost: $18,370 |
$5,650 | 166,178 | $1,706 | 24 | - | - | - | - | - | - |
$5,650 166,178 kWh |
$1,706 24 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $2,810 Cost: $500 |
- | - | - | - | $2,810 | 18,750 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,810 18,750 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $960 Cost: - |
$960 | 15,533 | - | - | - | - | - | - | - | - |
$960 15,533 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $154,858 Cost: $436,375 |
$10,442 | 242,965 | $1,706 | 24 | $2,810 | 18,750 | $75,400 | - | $64,500 | - | $10,442 242,965 kWh |
$1,706 24 kW-months/year |
$2,810 18,750 lb |
$75,400 - $ |
$64,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,310 Cost: $16,930 |
- | - | - | - | $2,810 | 18,750 | - | - | $37,500 | - | - - kWh |
- - kW-months/year |
$2,810 18,750 lb |
- - $ |
$37,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Primary Product |