Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Tennessee |
---|---|
Assessment Year | 2000 |
Principal Product | corrugated boxes |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 72 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 127,000,000 Thousand Feet |
Production Hrs. Annual | 4,340 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $39,907 | 1,022,861 | kWh | $0.04 |
Electricity Demand | $23,905 | 3,292 | kW-months/year | $7.26 |
Electricity Fees | $1,051 | - | $ | - |
Fuel Oil #2 | $17,730 | 3,165 | MMBtu | $5.60 |
TOTAL ENERGY COSTS | $288,866 | |||
RECOMMENDED SAVINGS* | $136,294 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $64,269 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1163 USE PLASTIC PALLETS INSTEAD OF WOOD |
Savings: $59,510 Cost: $6,500 |
- | - | - | - | $59,510 | 68,598 | - | - |
- - kWh |
- - kW-months/year |
$59,510 68,598 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $49,590 Cost: $3,000 |
- | - | - | - | $49,590 | 57,165 | - | - |
- - kWh |
- - kW-months/year |
$49,590 57,165 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $13,596 Cost: - |
$9,866 | 154,162 | $3,730 | 35 | - | - | - | - |
$9,866 154,162 kWh |
$3,730 35 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,460 Cost: $13,440 |
$5,650 | 87,925 | $1,810 | 17 | - | - | - | - |
$5,650 87,925 kWh |
$1,810 17 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $2,660 Cost: $1,075 |
- | - | - | - | - | - | $2,660 | - |
- - kWh |
- - kW-months/year |
- - lb |
$2,660 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,395 Cost: - |
$1,788 | 27,843 | $607 | 6 | - | - | - | - |
$1,788 27,843 kWh |
$607 6 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,083 Cost: $805 |
$678 | 10,551 | $405 | 4 | - | - | - | - |
$678 10,551 kWh |
$405 4 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $136,294 Cost: $24,820 |
$17,982 | 280,481 | $6,552 | 62 | $109,100 | 125,763 | $2,660 | - | $17,982 280,481 kWh |
$6,552 62 kW-months/year |
$109,100 125,763 lb |
$2,660 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $64,269 Cost: $3,805 |
$10,544 | 164,713 | $4,135 | 39 | $49,590 | 57,165 | - | - | $10,544 164,713 kWh |
$4,135 39 kW-months/year |
$49,590 57,165 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Product |