Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tri-Cities University
Assessment Year 1984
Principal Product SAFETY AND RELIEF VALVES
NAICS n/a
SIC 3494 - Valves And Pipe Fittings, Nec
Sales $10,000,000-$50,000,000
# of Employees 205
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $79,850 1,710,141 kWh $0.05
Natural Gas $28,650 6,590 MMBtu $4.35
Fuel Oil #2 $18,138 2,953 MMBtu $6.14
TOTAL ENERGY COSTS $126,638
RECOMMENDED SAVINGS* $15,522 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$3,244
Cost:
$500
- - $3,294 758 - - $(-50) - -
-
kWh
$3,294
758
MMBtu
-
-
MMBtu
$(-50)
-
$
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$246
Cost:
-
$94 2,052 $152 35 - - - - $94
2,052
kWh
$152
35
MMBtu
-
-
MMBtu
-
-
$
03: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS Savings:
$10,415
Cost:
-
- - $(-11,435) (-2,629) $21,850 2,953 - - -
-
kWh
$(-11,435)
(-2,629)
MMBtu
$21,850
2,953
MMBtu
-
-
$
04: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$677
Cost:
$2,376
- - $677 156 - - - - -
-
kWh
$677
156
MMBtu
-
-
MMBtu
-
-
$
05: 2.7441 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH Savings:
$217
Cost:
-
- - $217 50 - - - - -
-
kWh
$217
50
MMBtu
-
-
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$242
Cost:
$500
$242 5,275 - - - - - - $242
5,275
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$481
Cost:
$800
$481 10,258 - - - - - - $481
10,258
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$15,522
Cost:
$4,176
$817 17,585 $(-7,095) (-1,630) $21,850 2,953 $(-50) - $817
17,585
kWh
$(-7,095)
(-1,630)
MMBtu
$21,850
2,953
MMBtu
$(-50)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes Electricity Usage Natural Gas Fuel Oil #2 Administrative Changes