Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Tennessee Technological University
Assessment Year 2010
Principal Product Roasted Nuts
NAICS 311911 - Roasted Nuts and Peanut Butter Manufacturing
SIC 2068 - Salted And Roasted Nuts And Seeds
Sales <$500,000
# of Employees 330
Plant Area (Sq.Ft.) 158,000
Annual Production 54,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $438,153 7,494,840 kWh $0.06
Electricity Demand $154,320 13,376 kW-months/year $11.54
Natural Gas $106,464 16,808 MMBtu $6.33
TOTAL ENERGY COSTS $698,937
RECOMMENDED SAVINGS* $66,340 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,400
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Gaseous Waste Electricity Usage Electricity Demand Gaseous Waste
$ kWh $ kW-months/year $ lb
01: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$55,600
Cost:
-
- - - - $55,600 785,006 -
-
kWh
-
-
kW-months/year
$55,600
785,006
lb
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,700
Cost:
$10,500
$1,800 40,800 $2,900 196 - - $1,800
40,800
kWh
$2,900
196
kW-months/year
-
-
lb
03: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY Savings:
$3,000
Cost:
$10
$1,800 40,560 $1,200 78 - - $1,800
40,560
kWh
$1,200
78
kW-months/year
-
-
lb
04: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$2,700
Cost:
$1,000
- - - - $2,700 39,420 -
-
kWh
-
-
kW-months/year
$2,700
39,420
lb
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$340
Cost:
$520
$340 7,500 - - - - $340
7,500
kWh
-
-
kW-months/year
-
-
lb
TOTAL RECOMMENDED Savings:
$66,340
Cost:
$12,030
$3,940 88,860 $4,100 274 $58,300 824,426 $3,940
88,860
kWh
$4,100
274
kW-months/year
$58,300
824,426
lb
TOTAL IMPLEMENTED Savings:
$10,400
Cost:
$11,510
$3,600 81,360 $4,100 274 $2,700 39,420 $3,600
81,360
kWh
$4,100
274
kW-months/year
$2,700
39,420
lb
Savings
Cost
$ kWh $ kW-months/year $ lb