Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Tennessee Technological University |
---|---|
Assessment Year | 2014 |
Principal Product | smokeless tobacco products |
NAICS | 312230 - Tobacco Manufacturing |
SIC | 2131 - Chewing And Smoking Tobacco |
Sales | $100,000,000-$500,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 787,000 |
Annual Production | 2,335,880 Pieces |
Production Hrs. Annual | 4,250 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $983,286 | 17,316,600 | kWh | $0.06 |
Electricity Demand | $344,289 | 35,967 | kW-months/year | $9.57 |
Natural Gas | $256,570 | 49,520 | MMBtu | $5.18 |
TOTAL ENERGY COSTS | $1,695,917 | |||
RECOMMENDED SAVINGS* | $256,012 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $255,777 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $37,393 Cost: - |
$25,065 | 439,625 | - | - | $12,328 | 2,380 | - | - |
$25,065 439,625 kWh |
- - kW-months/year |
$12,328 2,380 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $8,930 Cost: - |
- | - | $8,930 | 933 | - | - | - | - |
- - kWh |
$8,930 933 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $235 Cost: - |
$191 | 3,363 | $44 | 5 | - | - | - | - |
$191 3,363 kWh |
$44 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $35,591 Cost: $18,500 |
$35,591 | 624,471 | - | - | - | - | - | - |
$35,591 624,471 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,060 Cost: $1,065 |
$540 | 9,490 | $27 | 3 | - | - | $494 | - |
$540 9,490 kWh |
$27 3 kW-months/year |
- - MMBtu |
$494 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $5,112 Cost: $17,178 |
$538 | 9,443 | $4,574 | 478 | - | - | - | - |
$538 9,443 kWh |
$4,574 478 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $125,381 Cost: $357,200 |
$85,058 | 1,492,260 | $40,323 | 4,213 | - | - | - | - |
$85,058 1,492,260 kWh |
$40,323 4,213 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $42,310 Cost: $281,250 |
$44,422 | 779,334 | $7,125 | 745 | $(-9,237) | (-1,783) | - | - |
$44,422 779,334 kWh |
$7,125 745 kW-months/year |
$(-9,237) (-1,783) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $256,012 Cost: $675,193 |
$191,405 | 3,357,986 | $61,022 | 6,376 | $3,091 | 597 | $494 | - | $191,405 3,357,986 kWh |
$61,022 6,376 kW-months/year |
$3,091 597 MMBtu |
$494 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $255,777 Cost: $675,193 |
$191,214 | 3,354,623 | $60,978 | 6,372 | $3,091 | 597 | $494 | - | $191,214 3,354,623 kWh |
$60,978 6,372 kW-months/year |
$3,091 597 MMBtu |
$494 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material |