Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2010 |
Principal Product | office furniture |
NAICS | 337211 - Wood Office Furniture Manufacturing |
SIC | 2521 - Wood Office Furniture |
Sales | $10,000,000-$50,000,000 |
# of Employees | 174 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 300,000 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $656,093 | 6,877,486 | kWh | $0.10 |
Electricity Demand | $256,572 | 19,292 | kW-months/year | $13.30 |
Natural Gas | $214,344 | 20,156 | MMBtu | $10.63 |
TOTAL ENERGY COSTS | $1,127,009 | |||
RECOMMENDED SAVINGS* | $229,287 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,282 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $65,946 Cost: $165,576 |
$48,536 | 510,528 | $17,410 | 1,309 | - | - |
$48,536 510,528 kWh |
$17,410 1,309 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,354 Cost: $253 |
$1,354 | 14,240 | - | - | - | - |
$1,354 14,240 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $53,011 Cost: $50,388 |
- | - | - | - | $53,011 | 4,987 |
- - kWh |
- - kW-months/year |
$53,011 4,987 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $29,964 Cost: $19,014 |
$14,177 | 148,486 | $15,787 | 1,187 | - | - |
$14,177 148,486 kWh |
$15,787 1,187 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $1,323 Cost: - |
$1,323 | 13,913 | - | - | - | - |
$1,323 13,913 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $35,672 Cost: $740 |
$20,922 | 220,006 | $14,750 | 1,109 | - | - |
$20,922 220,006 kWh |
$14,750 1,109 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $27,056 Cost: $4,100 |
- | - | - | - | $27,056 | 2,545 |
- - kWh |
- - kW-months/year |
$27,056 2,545 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,605 Cost: $5,500 |
$3,520 | 36,676 | $2,085 | 157 | - | - |
$3,520 36,676 kWh |
$2,085 157 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,519 Cost: $3,616 |
$4,003 | 42,111 | $1,516 | 114 | - | - |
$4,003 42,111 kWh |
$1,516 114 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,837 Cost: $10,250 |
$2,785 | 29,298 | $1,052 | 79 | - | - |
$2,785 29,298 kWh |
$1,052 79 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $229,287 Cost: $259,437 |
$96,620 | 1,015,258 | $52,600 | 3,955 | $80,067 | 7,532 | $96,620 1,015,258 kWh |
$52,600 3,955 kW-months/year |
$80,067 7,532 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,282 Cost: $5,753 |
$6,197 | 64,829 | $2,085 | 157 | - | - | $6,197 64,829 kWh |
$2,085 157 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||