Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Alabama |
---|---|
Assessment Year | 2014 |
Principal Product | lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 45,000 Thousand Feet |
Production Hrs. Annual | 2,350 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $358,831 | 5,185,200 | kWh | $0.07 |
Electricity Demand | $213,929 | 18,044 | kW-months/year | $11.86 |
Electricity Fees | $(-23,821) | - | $ | - |
Wood | $375,182 | 238,857 | MMBtu | $1.57 |
TOTAL ENERGY COSTS | $924,121 | |||
RECOMMENDED SAVINGS* | $77,541 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $41,922 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Wood | Electricity Usage | Electricity Demand | Electricity Fees | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,645 Cost: $52,587 |
$12,365 | 178,682 | $3,451 | 293 | $(-171) | - | - | - |
$12,365 178,682 kWh |
$3,451 293 kW-months/year |
$(-171) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,604 Cost: $1,767 |
$1,622 | 23,445 | - | - | $(-18) | - | - | - |
$1,622 23,445 kWh |
- - kW-months/year |
$(-18) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $7,137 Cost: $8,685 |
- | - | - | - | - | - | $7,137 | 4,543 |
- - kWh |
- - kW-months/year |
- - $ |
$7,137 4,543 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $34,015 Cost: $23,300 |
- | - | - | - | - | - | $34,015 | 21,652 |
- - kWh |
- - kW-months/year |
- - $ |
$34,015 21,652 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $10,076 Cost: $1,000 |
$4,750 | 71,518 | $5,436 | 458 | $(-110) | - | - | - |
$4,750 71,518 kWh |
$5,436 458 kW-months/year |
$(-110) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,506 Cost: $5,595 |
$2,761 | 39,896 | $1,794 | 151 | $(-49) | - | - | - |
$2,761 39,896 kWh |
$1,794 151 kW-months/year |
$(-49) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,559 Cost: $100 |
$964 | 13,932 | $612 | 52 | $(-17) | - | - | - |
$964 13,932 kWh |
$612 52 kW-months/year |
$(-17) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,999 Cost: $823 |
$3,032 | 43,811 | - | - | $(-33) | - | - | - |
$3,032 43,811 kWh |
- - kW-months/year |
$(-33) - $ |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,541 Cost: $93,857 |
$25,494 | 371,284 | $11,293 | 954 | $(-398) | - | $41,152 | 26,195 | $25,494 371,284 kWh |
$11,293 954 kW-months/year |
$(-398) - $ |
$41,152 26,195 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $41,922 Cost: $68,790 |
$23,872 | 347,839 | $11,293 | 954 | $(-380) | - | $7,137 | 4,543 | $23,872 347,839 kWh |
$11,293 954 kW-months/year |
$(-380) - $ |
$7,137 4,543 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Wood | Electricity Usage | Electricity Demand | Electricity Fees | Wood |