Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2022 |
Principal Product | Wastewater treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 12 |
Plant Area (Sq.Ft.) | 58,600 |
Annual Production | 2,920,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $450,627 | 4,782,240 | kWh | $0.09 |
Electricity Demand | $131,825 | 7,804 | kW-months/year | $16.89 |
Electricity Fees | $13,065 | - | $ | - |
Natural Gas | $37,272 | 3,911 | MMBtu | $9.53 |
TOTAL ENERGY COSTS | $632,789 | |||
RECOMMENDED SAVINGS* | $373,272 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,071 Cost: $2,641 |
$947 | 10,050 | $1,019 | 60 | - | - | $44 | - | - | - | $61 | - |
$947 10,050 kWh |
$1,019 60 kW-months/year |
- - $ |
$44 - $ |
- - $ |
$61 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $19,018 Cost: - |
$1,332 | 14,138 | $4,898 | 290 | $21,750 | - | $(-8,962) | - | - | - | - | - |
$1,332 14,138 kWh |
$4,898 290 kW-months/year |
$21,750 - $ |
$(-8,962) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $3,990 Cost: $500 |
$3,085 | 32,754 | $904 | 54 | - | - | - | - | - | - | - | - |
$3,085 32,754 kWh |
$904 54 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $2,840 Cost: $500 |
$2,283 | 24,235 | $557 | 33 | - | - | - | - | - | - | - | - |
$2,283 24,235 kWh |
$557 33 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $279,536 Cost: $1,875,313 |
$222,382 | 2,360,744 | $88,774 | 5,256 | - | - | - | - | $(-31,620) | - | - | - |
$222,382 2,360,744 kWh |
$88,774 5,256 kW-months/year |
- - $ |
- - $ |
$(-31,620) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $65,817 Cost: $383,577 |
$(-9,233) | (-98,013) | $81,072 | 4,800 | - | - | - | - | $(-6,022) | - | - | - |
$(-9,233) (-98,013) kWh |
$81,072 4,800 kW-months/year |
- - $ |
- - $ |
$(-6,022) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $373,272 Cost: $2,262,531 |
$220,796 | 2,343,908 | $177,224 | 10,493 | $21,750 | - | $(-8,918) | - | $(-37,642) | - | $61 | - | $220,796 2,343,908 kWh |
$177,224 10,493 kW-months/year |
$21,750 - $ |
$(-8,918) - $ |
$(-37,642) - $ |
$61 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost |