Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2022 |
Principal Product | Metal casting |
NAICS | 331524 - Aluminum Foundries (except Die-Casting) |
SIC | 3365 - Aluminum Foundries |
Sales | $10,000,000-$50,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 51,000 |
Annual Production | 10,000 Units |
Production Hrs. Annual | 2,000 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $78,401 | 744,960 | kWh | $0.11 |
Electricity Demand | $60,592 | 4,021 | kW-months/year | $15.07 |
Electricity Fees | $5,267 | - | $ | - |
Natural Gas | $7,063 | 402 | MMBtu | $17.57 |
Fuel Oil #2 | $13,647 | 522 | MMBtu | $26.15 |
TOTAL ENERGY COSTS | $164,970 | |||
RECOMMENDED SAVINGS* | $97,263 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $378 Cost: $464 |
$193 | 1,834 | $166 | 11 | - | - | - | - | $19 | - |
$193 1,834 kWh |
$166 11 kW-months/year |
- - MMBtu |
- - MMBtu |
$19 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,727 Cost: $500 |
$1,893 | 17,990 | $834 | 55 | - | - | - | - | - | - |
$1,893 17,990 kWh |
$834 55 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $12,731 Cost: $500 |
$12,731 | 120,957 | - | - | - | - | - | - | - | - |
$12,731 120,957 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,359 Cost: $2,800 |
$3,359 | 31,933 | - | - | - | - | - | - | - | - |
$3,359 31,933 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,876 Cost: $500 |
$2,876 | 27,331 | - | - | - | - | - | - | - | - |
$2,876 27,331 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $4,478 Cost: $3,300 |
- | - | - | - | $(-9,169) | (-522) | $13,647 | 522 | - | - |
- - kWh |
- - kW-months/year |
$(-9,169) (-522) MMBtu |
$13,647 522 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $70,713 Cost: $379,682 |
$59,314 | 563,821 | $18,988 | 1,260 | - | - | - | - | $(-7,589) | - |
$59,314 563,821 kWh |
$18,988 1,260 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-7,589) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $97,263 Cost: $387,746 |
$80,367 | 763,866 | $19,988 | 1,326 | $(-9,169) | (-522) | $13,647 | 522 | $(-7,570) | - | $80,367 763,866 kWh |
$19,988 1,326 kW-months/year |
$(-9,169) (-522) MMBtu |
$13,647 522 MMBtu |
$(-7,570) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes |