IAC logo
IAC Assessment: UC2207
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UC2207
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Connecticut
Assessment Year 2022
Principal Product Metal casting
NAICS 331524 - Aluminum Foundries (except Die-Casting)
SIC 3365 - Aluminum Foundries
Sales $10,000,000-$50,000,000
# of Employees 55
Plant Area (Sq.Ft.) 51,000
Annual Production 10,000 Units
Production Hrs. Annual 2,000
Location (State) CT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $78,401 744,960 kWh $0.11
Electricity Demand $60,592 4,021 kW-months/year $15.07
Electricity Fees $5,267 - $ -
Natural Gas $7,063 402 MMBtu $17.57
Fuel Oil #2 $13,647 522 MMBtu $26.15
TOTAL ENERGY COSTS $164,970
RECOMMENDED SAVINGS* $97,263 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Fuel Oil #2 Personnel Changes Electricity Usage Electricity Demand Natural Gas Fuel Oil #2 Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$378
Cost:
$464
$193 1,834 $166 11 - - - - $19 - $193
1,834
kWh
$166
11
kW-months/year
-
-
MMBtu
-
-
MMBtu
$19
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,727
Cost:
$500
$1,893 17,990 $834 55 - - - - - - $1,893
17,990
kWh
$834
55
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$12,731
Cost:
$500
$12,731 120,957 - - - - - - - - $12,731
120,957
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,359
Cost:
$2,800
$3,359 31,933 - - - - - - - - $3,359
31,933
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,876
Cost:
$500
$2,876 27,331 - - - - - - - - $2,876
27,331
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
06: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS Savings:
$4,478
Cost:
$3,300
- - - - $(-9,169) (-522) $13,647 522 - - -
-
kWh
-
-
kW-months/year
$(-9,169)
(-522)
MMBtu
$13,647
522
MMBtu
-
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$70,713
Cost:
$379,682
$59,314 563,821 $18,988 1,260 - - - - $(-7,589) - $59,314
563,821
kWh
$18,988
1,260
kW-months/year
-
-
MMBtu
-
-
MMBtu
$(-7,589)
-
$
TOTAL RECOMMENDED Savings:
$97,263
Cost:
$387,746
$80,367 763,866 $19,988 1,326 $(-9,169) (-522) $13,647 522 $(-7,570) - $80,367
763,866
kWh
$19,988
1,326
kW-months/year
$(-9,169)
(-522)
MMBtu
$13,647
522
MMBtu
$(-7,570)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Fuel Oil #2 Personnel Changes Electricity Usage Electricity Demand Natural Gas Fuel Oil #2 Personnel Changes