Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2023 |
Principal Product | Industrial heating equipment |
NAICS | 333994 - Industrial Process Furnace and Oven Manufacturing |
SIC | 3567 - Industrial Furnaces And Ovens |
Sales | $1,000,000-$5,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 47,000 |
Annual Production | 90,000 Pieces |
Production Hrs. Annual | 2,340 |
Location (State) | CT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $40,428 | 396,383 | kWh | $0.10 |
Electricity Demand | $35,396 | 1,578 | kW-months/year | $22.43 |
Electricity Fees | $3,764 | - | $ | - |
Natural Gas | $7,408 | 395 | MMBtu | $18.76 |
TOTAL ENERGY COSTS | $86,997 | |||
RECOMMENDED SAVINGS* | $75,935 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $269 Cost: - |
- | - | - | - | $269 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$269 - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $354 Cost: $222 |
$272 | 2,665 | $82 | 4 | - | - | - | - | - | - | - | - | - | - |
$272 2,665 kWh |
$82 4 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,868 Cost: $11,165 |
$3,781 | 37,066 | $4,263 | 190 | - | - | - | - | - | - | $(-267) | - | $91 | - |
$3,781 37,066 kWh |
$4,263 190 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$(-267) - $ |
$91 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $323 Cost: $855 |
$248 | 2,434 | $75 | 3 | - | - | - | - | - | - | - | - | - | - |
$248 2,434 kWh |
$75 3 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $534 Cost: $75 |
$410 | 4,023 | $124 | 6 | - | - | - | - | - | - | - | - | - | - |
$410 4,023 kWh |
$124 6 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,231 Cost: $150 |
$1,715 | 16,811 | $517 | 23 | - | - | - | - | - | - | - | - | - | - |
$1,715 16,811 kWh |
$517 23 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,770 Cost: $559 |
$112 | 1,100 | $34 | 2 | - | - | $1,624 | 87 | - | - | - | - | - | - |
$112 1,100 kWh |
$34 2 kW-months/year |
- - $ |
$1,624 87 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $3,601 Cost: $25,290 |
$(-651) | (-6,381) | $(-511) | (-23) | - | - | $4,763 | 254 | - | - | - | - | - | - |
$(-651) (-6,381) kWh |
$(-511) (-23) kW-months/year |
- - $ |
$4,763 254 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $5,665 Cost: $31,002 |
$(-998) | (-9,789) | $(-615) | (-27) | - | - | $7,279 | 388 | - | - | - | - | - | - |
$(-998) (-9,789) kWh |
$(-615) (-27) kW-months/year |
- - $ |
$7,279 388 MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $3,746 Cost: $34,025 |
$367 | 3,600 | $111 | 5 | $4,200 | - | $(-932) | (-49) | - | - | - | - | - | - |
$367 3,600 kWh |
$111 5 kW-months/year |
$4,200 - $ |
$(-932) (-49) MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $29,189 Cost: $268,543 |
$29,189 | 286,167 | - | - | - | - | - | - | - | - | - | - | - | - |
$29,189 286,167 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $9,576 Cost: $41,370 |
$(-868) | (-8,505) | $10,766 | 480 | $(-323) | - | - | - | - | - | - | - | - | - |
$(-868) (-8,505) kWh |
$10,766 480 kW-months/year |
$(-323) - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $10,809 Cost: $60,198 |
$(-2,921) | (-28,634) | $(-879) | (-39) | - | - | - | - | $14,608 | - | - | - | - | - |
$(-2,921) (-28,634) kWh |
$(-879) (-39) kW-months/year |
- - $ |
- - MMBtu |
$14,608 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $75,935 Cost: $473,454 |
$30,657 | 300,557 | $13,966 | 623 | $4,147 | - | $12,734 | 680 | $14,608 | - | $(-267) | - | $91 | - | $30,657 300,557 kWh |
$13,966 623 kW-months/year |
$4,147 - $ |
$12,734 680 MMBtu |
$14,608 - $ |
$(-267) - $ |
$91 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Primary Raw Material | Ancillary Material Cost | One-time Revenue or Avoided Cost |