Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Connecticut |
---|---|
Assessment Year | 2024 |
Principal Product | Semiconductor wafers |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $5,000,000-$10,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 92,600 |
Annual Production | 130,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,034,443 | 9,948,743 | kWh | $0.10 |
Electricity Demand | $356,769 | 15,359 | kW-months/year | $23.23 |
Natural Gas | $459,494 | 53,316 | MMBtu | $8.62 |
TOTAL ENERGY COSTS | $1,850,705 | |||
RECOMMENDED SAVINGS* | $635,086 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $19,662 Cost: $1,600 |
$15,055 | 144,761 | $4,607 | 198 | - | - | - | - |
$15,055 144,761 kWh |
$4,607 198 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $159,604 Cost: $5,236 |
$98,630 | 948,361 | $30,179 | 1,299 | $30,796 | 3,573 | - | - |
$98,630 948,361 kWh |
$30,179 1,299 kW-months/year |
$30,796 3,573 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,767 Cost: $1,553 |
$1,239 | 11,914 | $379 | 16 | - | - | $149 | - |
$1,239 11,914 kWh |
$379 16 kW-months/year |
- - MMBtu |
$149 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $510 Cost: $218 |
$456 | 4,380 | - | - | - | - | $55 | - |
$456 4,380 kWh |
- - kW-months/year |
- - MMBtu |
$55 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $73,494 Cost: $29,062 |
$56,275 | 541,105 | $17,219 | 741 | - | - | - | - |
$56,275 541,105 kWh |
$17,219 741 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,536 Cost: $1,750 |
- | - | - | - | $3,536 | 410 | - | - |
- - kWh |
- - kW-months/year |
$3,536 410 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $294 Cost: $139 |
- | - | - | - | $294 | 34 | - | - |
- - kWh |
- - kW-months/year |
$294 34 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $240,811 Cost: $2,527,500 |
$184,391 | 1,772,991 | $56,420 | 2,429 | - | - | - | - |
$184,391 1,772,991 kWh |
$56,420 2,429 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $80,097 Cost: $301,647 |
$61,331 | 589,723 | $18,766 | 808 | - | - | - | - |
$61,331 589,723 kWh |
$18,766 808 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $55,311 Cost: $819,496 |
$268,843 | 2,585,030 | $6,855 | 295 | $(-220,387) | (-25,576) | - | - |
$268,843 2,585,030 kWh |
$6,855 295 kW-months/year |
$(-220,387) (-25,576) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $635,086 Cost: $3,688,201 |
$686,220 | 6,598,266 | $134,424 | 5,787 | $(-185,761) | (-21,559) | $204 | - | $686,220 6,598,266 kWh |
$134,424 5,787 kW-months/year |
$(-185,761) (-21,559) MMBtu |
$204 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |