Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1989
Principal Product WHEELS & BLOWERS
NAICS n/a
SIC 3498 - Fabricated Pipe And Fittings
Sales $5,000,000-$10,000,000
# of Employees 130
Plant Area (Sq.Ft.) 0
Annual Production 65,000 Pieces
Production Hrs. Annual 2,040
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $110,597 1,665,885 kWh $0.07
Natural Gas $117,876 28,720 MMBtu $4.10
TOTAL ENERGY COSTS $228,473
RECOMMENDED SAVINGS* $24,490 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,809
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$3,618
Cost:
$1,000
- - $3,618 853 - - -
-
kWh
$3,618
853
MMBtu
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$2,453
Cost:
-
$2,453 - - - - - $2,453
-
kWh
-
-
MMBtu
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,150
Cost:
$4,000
$2,656 39,859 $(-506) (-124) - - $2,656
39,859
kWh
$(-506)
(-124)
MMBtu
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$791
Cost:
$1,000
$977 14,654 $(-186) (-46) - - $977
14,654
kWh
$(-186)
(-46)
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$356
Cost:
$75
$432 5,275 - - $(-76) - $432
5,275
kWh
-
-
MMBtu
$(-76)
-
$
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$9,331
Cost:
$25,000
- - $9,331 2,287 - - -
-
kWh
$9,331
2,287
MMBtu
-
-
$
07: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$5,791
Cost:
$20,000
$596 5,275 - - $5,195 - $596
5,275
kWh
-
-
MMBtu
$5,195
-
$
TOTAL RECOMMENDED Savings:
$24,490
Cost:
$51,075
$7,114 65,063 $12,257 2,970 $5,119 - $7,114
65,063
kWh
$12,257
2,970
MMBtu
$5,119
-
$
TOTAL IMPLEMENTED Savings:
$2,809
Cost:
$75
$2,885 5,275 - - $(-76) - $2,885
5,275
kWh
-
-
MMBtu
$(-76)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes