IAC logo
IAC Assessment: UD0416
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD0416
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 1993
Principal Product Steel Waste receptacles
NAICS n/a
SIC 3411 - Metal Cans
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 20,000
Annual Production 0 Units
Production Hrs. Annual 8,340
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $79,133 1,381,594 kWh $0.06
Natural Gas $153,950 42,446 MMBtu $3.63
TOTAL ENERGY COSTS $233,083
RECOMMENDED SAVINGS* $32,313 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $10,224
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$2,440
Cost:
-
$2,440 - - - $2,440
-
kWh
-
-
MMBtu
02: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$17,440
Cost:
$20,000
- - $17,440 - -
-
kWh
$17,440
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,163
Cost:
$2,170
$1,163 14,654 - - $1,163
14,654
kWh
-
-
MMBtu
04: 2.2422 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM Savings:
$9,061
Cost:
$3,000
$8,026 252,345 $1,035 314 $8,026
252,345
kWh
$1,035
314
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,209
Cost:
-
- - $2,209 669 -
-
kWh
$2,209
669
MMBtu
TOTAL RECOMMENDED Savings:
$32,313
Cost:
$25,170
$11,629 266,999 $20,684 983 $11,629
266,999
kWh
$20,684
983
MMBtu
TOTAL IMPLEMENTED Savings:
$10,224
Cost:
$5,170
$9,189 266,999 $1,035 314 $9,189
266,999
kWh
$1,035
314
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas