Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1996 |
Principal Product | folding cartons |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 89 |
Plant Area (Sq.Ft.) | 188,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,500 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $113,355 | 3,818,582 | kWh | $0.03 |
Electricity Demand | $101,948 | 9,444 | kW-months/year | $10.80 |
Natural Gas | $33,634 | 7,090 | MMBtu | $4.74 |
TOTAL ENERGY COSTS | $248,937 | |||
RECOMMENDED SAVINGS* | $41,819 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,396 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $12,517 Cost: $14,000 |
$5,607 | 264,947 | $4,994 | 348 | - | - | - | - | - | - | - | - | $1,916 | - |
$5,607 264,947 kWh |
$4,994 348 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
$1,916 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $7,890 Cost: - |
- | - | $8,610 | 600 | - | - | - | - | $(-720) | - | - | - | - | - |
- - kWh |
$8,610 600 kW-months/year |
- - MMBtu |
- - gal |
$(-720) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $12,533 Cost: - |
$4,935 | 186,108 | $3,368 | 312 | $4,230 | 900 | - | - | - | - | - | - | - | - |
$4,935 186,108 kWh |
$3,368 312 kW-months/year |
$4,230 900 MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7122 DISCONNECT BALLASTS |
Savings: $1,437 Cost: $1,650 |
$664 | 31,653 | $641 | 45 | - | - | - | - | - | - | $132 | - | - | - |
$664 31,653 kWh |
$641 45 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$132 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,632 Cost: $12,454 |
$2,696 | 128,370 | $3,936 | 274 | - | - | - | - | - | - | - | - | - | - |
$2,696 128,370 kWh |
$3,936 274 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $810 Cost: - |
- | - | - | - | - | - | $810 | 495 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$810 495 gal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,819 Cost: $28,104 |
$13,902 | 611,078 | $21,549 | 1,579 | $4,230 | 900 | $810 | 495 | $(-720) | - | $132 | - | $1,916 | - | $13,902 611,078 kWh |
$21,549 1,579 kW-months/year |
$4,230 900 MMBtu |
$810 495 gal |
$(-720) - $ |
$132 - $ |
$1,916 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,396 Cost: $28,104 |
$8,967 | 424,970 | $9,571 | 667 | - | - | $810 | 495 | - | - | $132 | - | $1,916 | - | $8,967 424,970 kWh |
$9,571 667 kW-months/year |
- - MMBtu |
$810 495 gal |
- - $ |
$132 - $ |
$1,916 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |