Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1996 |
Principal Product | bronzed baby shoes |
NAICS | n/a |
SIC | 3471 - Plating And Polishing |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 2,100 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $46,917 | 691,383 | kWh | $0.07 |
Electricity Demand | $13,361 | 3,516 | kW-months/year | $3.80 |
Natural Gas | $33,781 | 6,979 | MMBtu | $4.84 |
TOTAL ENERGY COSTS | $112,878 | |||
RECOMMENDED SAVINGS* | $12,153 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $866 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $6,700 Cost: $2,000 |
$(-109) | (-1,758) | $(-36) | (-10) | - | - | $6,845 | 1,080,112 | - | - | - | - | - | - |
$(-109) (-1,758) kWh |
$(-36) (-10) kW-months/year |
- - MMBtu |
$6,845 1,080,112 Tgal |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $2,200 Cost: $600 |
- | - | - | - | - | - | - | - | $1,600 | 160 | $600 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$1,600 160 gal |
$600 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $866 Cost: - |
- | - | $866 | 228 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$866 228 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $656 Cost: $700 |
$347 | 5,275 | $116 | 31 | $(-63) | (-13) | - | - | - | - | - | - | $256 | - |
$347 5,275 kWh |
$116 31 kW-months/year |
$(-63) (-13) MMBtu |
- - Tgal |
- - gal |
- - lb |
$256 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,731 Cost: $6,298 |
$384 | 18,171 | $1,347 | 105 | - | - | - | - | - | - | - | - | - | - |
$384 18,171 kWh |
$1,347 105 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $12,153 Cost: $9,598 |
$622 | 21,688 | $2,293 | 354 | $(-63) | (-13) | $6,845 | 1,080,112 | $1,600 | 160 | $600 | - | $256 | - | $622 21,688 kWh |
$2,293 354 kW-months/year |
$(-63) (-13) MMBtu |
$6,845 1,080,112 Tgal |
$1,600 160 gal |
$600 - lb |
$256 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $866 Cost: - |
- | - | $866 | 228 | - | - | - | - | - | - | - | - | - | - | - - kWh |
$866 228 kW-months/year |
- - MMBtu |
- - Tgal |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Other Liquid (haz) | Solid Waste (non-haz) | Administrative Changes |