Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1997 |
Principal Product | Plastic Pipe Fittings |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | n/a |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 115,000 |
Annual Production | 12,000,000 Pounds |
Production Hrs. Annual | 6,396 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $146,130 | 6,960,727 | kWh | $0.02 |
Electricity Demand | $181,165 | 12,876 | kW-months/year | $14.07 |
Natural Gas | $94,812 | 18,969 | MMBtu | $5.00 |
TOTAL ENERGY COSTS | $422,107 | |||
RECOMMENDED SAVINGS* | $246,834 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $115,811 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,963 Cost: $4,000 |
$(-1,298) | (-61,841) | $(-1,739) | (-124) | $5,000 | 1,000 | - | - |
$(-1,298) (-61,841) kWh |
$(-1,739) (-124) kW-months/year |
$5,000 1,000 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,322 Cost: $8,719 |
$1,117 | 53,341 | $2,205 | 157 | - | - | - | - |
$1,117 53,341 kWh |
$2,205 157 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,731 Cost: $150 |
- | - | $1,731 | 123 | - | - | - | - |
- - kWh |
$1,731 123 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $756 Cost: $2,099 |
$377 | 17,878 | $379 | 27 | - | - | - | - |
$377 17,878 kWh |
$379 27 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6213 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS |
Savings: $1,589 Cost: $1,000 |
$1,589 | 75,615 | - | - | - | - | - | - |
$1,589 75,615 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6213 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS |
Savings: $13,703 Cost: $1,600 |
$3,203 | 152,696 | - | - | - | - | $10,500 | - |
$3,203 152,696 kWh |
- - kW-months/year |
- - MMBtu |
$10,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7446 UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS |
Savings: $23,470 Cost: $200 |
- | - | - | - | $3,556 | 711 | $19,914 | - |
- - kWh |
- - kW-months/year |
$3,556 711 MMBtu |
$19,914 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $71,600 Cost: $21,000 |
- | - | - | - | - | - | $71,600 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$71,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $8,400 Cost: $10,000 |
- | - | - | - | - | - | $8,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $6,300 Cost: $448 |
- | - | - | - | - | - | $6,300 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.113 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT |
Savings: $114,000 Cost: $5,000 |
- | - | - | - | - | - | $114,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$114,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $246,834 Cost: $54,216 |
$4,988 | 237,689 | $2,576 | 183 | $8,556 | 1,711 | $230,714 | - | $4,988 237,689 kWh |
$2,576 183 kW-months/year |
$8,556 1,711 MMBtu |
$230,714 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $115,811 Cost: $46,466 |
$196 | 9,378 | $845 | 60 | $8,556 | 1,711 | $106,214 | - | $196 9,378 kWh |
$845 60 kW-months/year |
$8,556 1,711 MMBtu |
$106,214 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |