Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1997 |
Principal Product | Labels & Tags |
NAICS | n/a |
SIC | 2671 - Paper Coated & Laminated, Packaging |
Sales | n/a |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 144,000,000 Thousand Feet |
Production Hrs. Annual | 7,800 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $29,724 | 1,415,885 | kWh | $0.02 |
Electricity Demand | $50,958 | 3,252 | kW-months/year | $15.67 |
Natural Gas | $4,586 | 756 | MMBtu | $6.07 |
TOTAL ENERGY COSTS | $85,268 | |||
RECOMMENDED SAVINGS* | $46,228 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (haz) | Personnel Changes | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $21,625 Cost: $250 |
$21,625 | 1,380 | - | - | - | - | - | - | - | - |
$21,625 1,380 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,672 Cost: $6,965 |
$2,672 | 168 | - | - | - | - | - | - | - | - |
$2,672 168 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,121 Cost: $1,020 |
- | - | $2,121 | 350 | - | - | - | - | - | - |
- - kW-months/year |
$2,121 350 MMBtu |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5211 REUSE SCRAP GLASS AS FEED STOCK |
Savings: $4,800 Cost: - |
- | - | - | - | - | - | $4,800 | - | - | - |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$4,800 - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4151 MINIMIZE WATER USAGE |
Savings: $15,010 Cost: $5,000 |
- | - | $(-1,070) | (-177) | $17,080 | 9,515 | - | - | $(-1,000) | - |
- - kW-months/year |
$(-1,070) (-177) MMBtu |
$17,080 9,515 Tgal |
- - lb |
$(-1,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,228 Cost: $13,235 |
$24,297 | 1,548 | $1,051 | 173 | $17,080 | 9,515 | $4,800 | - | $(-1,000) | - | $24,297 1,548 kW-months/year |
$1,051 173 MMBtu |
$17,080 9,515 Tgal |
$4,800 - lb |
$(-1,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Demand | Natural Gas | Water Disposal | Solid Waste (haz) | Personnel Changes | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (haz) | Personnel Changes |