Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1997 |
Principal Product | jellies, sauces, vinaigrettes, & mustard |
NAICS | n/a |
SIC | 2032 - Canned Specialties |
Sales | n/a |
# of Employees | 45 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 3,300 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $35,852 | 360,199 | kWh | $0.10 |
Electricity Demand | $1,520 | 108 | kW-months/year | $14.07 |
Electricity Fees | $5,079 | - | $ | - |
LPG | $8,473 | 919 | MMBtu | $9.22 |
TOTAL ENERGY COSTS | $50,924 | |||
RECOMMENDED SAVINGS* | $25,333 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,333 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5124 USE GRAVITY FEEDS WHEREVER POSSIBLE |
Savings: $9,099 Cost: $5,828 |
$195 | 7,327 | $2,904 | 208 | $4,280 | - | $1,720 | - |
$195 7,327 kWh |
$2,904 208 kW-months/year |
$4,280 - $ |
$1,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $557 Cost: $1,915 |
$192 | 7,034 | $365 | 26 | - | - | - | - |
$192 7,034 kWh |
$365 26 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $453 Cost: $888 |
$156 | 5,862 | $297 | 21 | - | - | - | - |
$156 5,862 kWh |
$297 21 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $811 Cost: - |
- | - | $304 | 22 | $507 | - | - | - |
- - kWh |
$304 22 kW-months/year |
$507 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $14,413 Cost: $6,000 |
$(-134) | (-4,982) | $(-253) | (-18) | - | - | $14,800 | - |
$(-134) (-4,982) kWh |
$(-253) (-18) kW-months/year |
- - $ |
$14,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,333 Cost: $14,631 |
$409 | 15,241 | $3,617 | 259 | $4,787 | - | $16,520 | - | $409 15,241 kWh |
$3,617 259 kW-months/year |
$4,787 - $ |
$16,520 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,333 Cost: $14,631 |
$409 | 15,241 | $3,617 | 259 | $4,787 | - | $16,520 | - | $409 15,241 kWh |
$3,617 259 kW-months/year |
$4,787 - $ |
$16,520 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |