Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1997 |
Principal Product | Fabricated Rubber Products |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 0 Thousand Feet |
Production Hrs. Annual | 3,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $107,050 | 5,027,257 | kWh | $0.02 |
Electricity Demand | $141,254 | 13,440 | kW-months/year | $10.51 |
Natural Gas | $268,483 | 70,273 | MMBtu | $3.82 |
TOTAL ENERGY COSTS | $603,582 | |||
RECOMMENDED SAVINGS* | $95,607 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,006 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,126 Cost: $6,975 |
$1,571 | 73,857 | $1,555 | 147 | - | - | - | - | - | - |
$1,571 73,857 kWh |
$1,555 147 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $647 Cost: $2,000 |
$408 | 19,050 | $239 | 23 | - | - | - | - | - | - |
$408 19,050 kWh |
$239 23 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,104 Cost: $16,862 |
$1,636 | 76,788 | $1,468 | 140 | - | - | - | - | - | - |
$1,636 76,788 kWh |
$1,468 140 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $33,190 Cost: $7,500 |
$4,481 | 210,434 | $7,819 | 744 | - | - | $20,890 | 5,745,039 | - | - |
$4,481 210,434 kWh |
$7,819 744 kW-months/year |
- - MMBtu |
$20,890 5,745,039 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $22,129 Cost: $4,000 |
- | - | - | - | - | - | $22,129 | 6,085,687 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$22,129 6,085,687 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $18,194 Cost: $10,000 |
$(-180) | (-8,499) | $(-164) | (-16) | - | - | $19,038 | 5,255,072 | $(-500) | - |
$(-180) (-8,499) kWh |
$(-164) (-16) kW-months/year |
- - MMBtu |
$19,038 5,255,072 Tgal |
$(-500) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4151 MINIMIZE WATER USAGE |
Savings: $3,644 Cost: $3,500 |
$(-4) | (-293) | - | - | - | - | $3,648 | 1,003,183 | - | - |
$(-4) (-293) kWh |
- - kW-months/year |
- - MMBtu |
$3,648 1,003,183 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $11,573 Cost: $5,000 |
$4,568 | 214,537 | $10,481 | 997 | $(-3,476) | (-915) | - | - | - | - |
$4,568 214,537 kWh |
$10,481 997 kW-months/year |
$(-3,476) (-915) MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $95,607 Cost: $55,837 |
$12,480 | 585,874 | $21,398 | 2,035 | $(-3,476) | (-915) | $65,705 | 18,088,981 | $(-500) | - | $12,480 585,874 kWh |
$21,398 2,035 kW-months/year |
$(-3,476) (-915) MMBtu |
$65,705 18,088,981 Tgal |
$(-500) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,006 Cost: $29,837 |
$3,615 | 169,695 | $3,262 | 310 | - | - | $22,129 | 6,085,687 | - | - | $3,615 169,695 kWh |
$3,262 310 kW-months/year |
- - MMBtu |
$22,129 6,085,687 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |