Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1998 |
Principal Product | Precast and prestressed concrete products |
NAICS | n/a |
SIC | 3272 - Concrete Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 4,050 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $31,433 | 1,209,261 | kWh | $0.03 |
Electricity Demand | $66,016 | 4,692 | kW-months/year | $14.07 |
Natural Gas | $56,926 | 10,516 | MMBtu | $5.41 |
TOTAL ENERGY COSTS | $154,375 | |||
RECOMMENDED SAVINGS* | $14,337 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,332 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $4,349 Cost: - |
- | - | - | - | - | - | $4,349 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,349 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,580 Cost: - |
$1,737 | 66,823 | - | - | - | - | $843 | - | - | - |
$1,737 66,823 kWh |
- - kW-months/year |
- - MMBtu |
$843 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,450 Cost: $6,900 |
$588 | 22,567 | $1,675 | 119 | - | - | $187 | - | - | - |
$588 22,567 kWh |
$1,675 119 kW-months/year |
- - MMBtu |
$187 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,403 Cost: $4,000 |
$876 | 33,705 | $2,246 | 160 | $(-719) | (-144) | - | - | - | - |
$876 33,705 kWh |
$2,246 160 kW-months/year |
$(-719) (-144) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $1,933 Cost: - |
- | - | - | - | - | - | - | - | $1,933 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,933 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $622 Cost: $600 |
- | - | - | - | $622 | 124 | - | - | - | - |
- - kWh |
- - kW-months/year |
$622 124 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,337 Cost: $11,500 |
$3,201 | 123,095 | $3,921 | 279 | $(-97) | (-20) | $5,379 | - | $1,933 | - | $3,201 123,095 kWh |
$3,921 279 kW-months/year |
$(-97) (-20) MMBtu |
$5,379 - $ |
$1,933 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,332 Cost: $4,000 |
$2,613 | 100,528 | $2,246 | 160 | $(-719) | (-144) | $5,192 | - | - | - | $2,613 100,528 kWh |
$2,246 160 kW-months/year |
$(-719) (-144) MMBtu |
$5,192 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost |