Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 1999 |
Principal Product | aluminum die castings |
NAICS | n/a |
SIC | 3363 - Aluminum Die-castings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 135 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 5,000,000 Pounds |
Production Hrs. Annual | 7,344 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $58,165 | 2,721,278 | kWh | $0.02 |
Electricity Demand | $91,602 | 6,492 | kW-months/year | $14.11 |
Natural Gas | $236,181 | 70,307 | MMBtu | $3.36 |
TOTAL ENERGY COSTS | $396,002 | |||
RECOMMENDED SAVINGS* | $301,743 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $50,275 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $220,632 Cost: $300,000 |
- | - | - | - | - | - | - | - | $205,632 | - | $15,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$205,632 - $ |
$15,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $22,972 Cost: $148 |
$10,950 | 527,257 | $12,022 | 852 | - | - | - | - | - | - | - | - |
$10,950 527,257 kWh |
$12,022 852 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $22,776 Cost: $49,660 |
- | - | - | - | $22,776 | 6,699 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$22,776 6,699 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2514 COVER OPEN TANKS |
Savings: $13,847 Cost: $2,400 |
- | - | - | - | $13,847 | 4,073 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,847 4,073 MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $10,689 Cost: - |
- | - | $10,689 | 757 | - | - | - | - | - | - | - | - |
- - kWh |
$10,689 757 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4155 METER WASTE WATER |
Savings: $5,686 Cost: $2,200 |
- | - | - | - | - | - | $5,686 | 1,890,327 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,686 1,890,327 gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $2,767 Cost: $3,375 |
$478 | 22,860 | $525 | 37 | - | - | - | - | $1,764 | - | - | - |
$478 22,860 kWh |
$525 37 kW-months/year |
- - MMBtu |
- - gal |
$1,764 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,156 Cost: $5,096 |
$1,104 | 52,462 | $1,212 | 86 | - | - | - | - | $(-160) | - | - | - |
$1,104 52,462 kWh |
$1,212 86 kW-months/year |
- - MMBtu |
- - gal |
$(-160) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $218 Cost: $684 |
$56 | 2,638 | $91 | 6 | - | - | - | - | - | - | $71 | - |
$56 2,638 kWh |
$91 6 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
$71 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $301,743 Cost: $363,563 |
$12,588 | 605,217 | $24,539 | 1,738 | $36,623 | 10,772 | $5,686 | 1,890,327 | $207,236 | - | $15,071 | - | $12,588 605,217 kWh |
$24,539 1,738 kW-months/year |
$36,623 10,772 MMBtu |
$5,686 1,890,327 gal |
$207,236 - $ |
$15,071 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $50,275 Cost: $5,923 |
$11,428 | 550,117 | $23,236 | 1,646 | $13,847 | 4,073 | - | - | $1,764 | - | - | - | $11,428 550,117 kWh |
$23,236 1,646 kW-months/year |
$13,847 4,073 MMBtu |
- - gal |
$1,764 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Personnel Changes | Administrative Changes |