Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2000 |
Principal Product | Gray, Ductile, Alloy, Steel & Iron Casting |
NAICS | n/a |
SIC | 3321 - Gray And Ductile Iron Foundries |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 15,587,913 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $582,075 | 14,549,238 | kWh | $0.04 |
Electricity Demand | $100,992 | 12,624 | kW-months/year | $8.00 |
LPG | $109,754 | 26,124 | MMBtu | $4.20 |
TOTAL ENERGY COSTS | $853,071 | |||
RECOMMENDED SAVINGS* | $58,121 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $50,153 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $27,415 Cost: $15,000 |
- | - | - | - | - | - | $27,415 | 7,918,639 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$27,415 7,918,639 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $13,231 Cost: $1,200 |
- | - | - | - | - | - | - | - | $13,231 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$13,231 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,027 Cost: $6,250 |
$3,395 | 106,096 | $1,632 | 204 | - | - | - | - | - | - |
$3,395 106,096 kWh |
$1,632 204 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,480 Cost: $14,755 |
$3,136 | 90,270 | $1,344 | 168 | - | - | - | - | - | - |
$3,136 90,270 kWh |
$1,344 168 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,156 Cost: $3,500 |
- | - | - | - | $4,156 | 971 | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,156 971 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,103 Cost: - |
$1,514 | 47,186 | $589 | 73 | - | - | - | - | - | - |
$1,514 47,186 kWh |
$589 73 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,709 Cost: $4,624 |
$1,035 | 32,239 | $674 | 84 | - | - | - | - | - | - |
$1,035 32,239 kWh |
$674 84 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $58,121 Cost: $45,329 |
$9,080 | 275,791 | $4,239 | 529 | $4,156 | 971 | $27,415 | 7,918,639 | $13,231 | - | $9,080 275,791 kWh |
$4,239 529 kW-months/year |
$4,156 971 MMBtu |
$27,415 7,918,639 Tgal |
$13,231 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $50,153 Cost: $37,205 |
$6,531 | 196,366 | $2,976 | 372 | - | - | $27,415 | 7,918,639 | $13,231 | - | $6,531 196,366 kWh |
$2,976 372 kW-months/year |
- - MMBtu |
$27,415 7,918,639 Tgal |
$13,231 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes |