Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2000
Principal Product Gray, Ductile, Alloy, Steel & Iron Casting
NAICS n/a
SIC 3321 - Gray And Ductile Iron Foundries
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 60,000
Annual Production 15,587,913 Pounds
Production Hrs. Annual 6,240
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $582,075 14,549,238 kWh $0.04
Electricity Demand $100,992 12,624 kW-months/year $8.00
LPG $109,754 26,124 MMBtu $4.20
TOTAL ENERGY COSTS $853,071
RECOMMENDED SAVINGS* $58,121 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $50,153
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER Savings:
$27,415
Cost:
$15,000
- - - - - - $27,415 7,918,639 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$27,415
7,918,639
Tgal
-
-
$
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$13,231
Cost:
$1,200
- - - - - - - - $13,231 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$13,231
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,027
Cost:
$6,250
$3,395 106,096 $1,632 204 - - - - - - $3,395
106,096
kWh
$1,632
204
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,480
Cost:
$14,755
$3,136 90,270 $1,344 168 - - - - - - $3,136
90,270
kWh
$1,344
168
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$4,156
Cost:
$3,500
- - - - $4,156 971 - - - - -
-
kWh
-
-
kW-months/year
$4,156
971
MMBtu
-
-
Tgal
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,103
Cost:
-
$1,514 47,186 $589 73 - - - - - - $1,514
47,186
kWh
$589
73
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,709
Cost:
$4,624
$1,035 32,239 $674 84 - - - - - - $1,035
32,239
kWh
$674
84
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$58,121
Cost:
$45,329
$9,080 275,791 $4,239 529 $4,156 971 $27,415 7,918,639 $13,231 - $9,080
275,791
kWh
$4,239
529
kW-months/year
$4,156
971
MMBtu
$27,415
7,918,639
Tgal
$13,231
-
$
TOTAL IMPLEMENTED Savings:
$50,153
Cost:
$37,205
$6,531 196,366 $2,976 372 - - $27,415 7,918,639 $13,231 - $6,531
196,366
kWh
$2,976
372
kW-months/year
-
-
MMBtu
$27,415
7,918,639
Tgal
$13,231
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes