Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2001 |
Principal Product | Aerospace Products |
NAICS | n/a |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 78,000 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 7,344 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $141,913 | 6,450,600 | kWh | $0.02 |
Electricity Demand | $160,541 | 11,928 | kW-months/year | $13.46 |
Natural Gas | $94,584 | 16,254 | MMBtu | $5.82 |
TOTAL ENERGY COSTS | $415,416 | |||
RECOMMENDED SAVINGS* | $73,943 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,863 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5112 REPROCESS SPENT OILS ON SITE FOR RE-USE |
Savings: $39,420 Cost: - |
- | - | - | - | - | - | $3,780 | 10,800 | - | - | $35,640 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,780 10,800 gal |
- - lb |
$35,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $11,768 Cost: - |
$1,082 | 49,200 | - | - | $10,686 | 1,836 | - | - | - | - | - | - |
$1,082 49,200 kWh |
- - kW-months/year |
$10,686 1,836 MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $7,723 Cost: - |
$3,016 | 137,088 | $4,707 | 336 | - | - | - | - | - | - | - | - |
$3,016 137,088 kWh |
$4,707 336 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $7,298 Cost: $3,000 |
- | - | - | - | - | - | - | - | $7,298 | 62,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$7,298 62,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $5,092 Cost: $2,000 |
- | - | - | - | - | - | - | - | - | - | $5,092 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$5,092 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,280 Cost: $2,460 |
- | - | - | - | $1,280 | 220 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,280 220 MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $966 Cost: $2,220 |
$630 | 14,688 | $336 | 24 | - | - | - | - | - | - | - | - |
$630 14,688 kWh |
$336 24 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $396 Cost: - |
$194 | 8,813 | $202 | 14 | - | - | - | - | - | - | - | - |
$194 8,813 kWh |
$202 14 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,943 Cost: $9,680 |
$4,922 | 209,789 | $5,245 | 374 | $11,966 | 2,056 | $3,780 | 10,800 | $7,298 | 62,000 | $40,732 | - | $4,922 209,789 kWh |
$5,245 374 kW-months/year |
$11,966 2,056 MMBtu |
$3,780 10,800 gal |
$7,298 62,000 lb |
$40,732 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,863 Cost: $4,460 |
$4,098 | 186,288 | $4,707 | 336 | $11,966 | 2,056 | - | - | - | - | $5,092 | - | $4,098 186,288 kWh |
$4,707 336 kW-months/year |
$11,966 2,056 MMBtu |
- - gal |
- - lb |
$5,092 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Administrative Changes |