Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2002 |
Principal Product | Dog cat and small animal feed |
NAICS | n/a |
SIC | 2047 - Dog And Cat Food |
Sales | $10,000,000-$50,000,000 |
# of Employees | 48 |
Plant Area (Sq.Ft.) | 95,000 |
Annual Production | 50,000 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $169,272 | 5,044,906 | kWh | $0.03 |
Electricity Demand | $106,547 | 13,572 | kW-months/year | $7.85 |
Natural Gas | $319,555 | 53,767 | MMBtu | $5.94 |
TOTAL ENERGY COSTS | $610,487 | |||
RECOMMENDED SAVINGS* | $180,743 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $161,974 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $147,420 Cost: - |
- | - | - | - | - | - | - | - | $147,420 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$147,420 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $13,350 Cost: $1,122 |
$9,123 | 268,320 | $4,227 | 536 | - | - | - | - | - | - |
$9,123 268,320 kWh |
$4,227 536 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,888 Cost: - |
- | - | $8,888 | 1,128 | - | - | - | - | - | - |
- - kWh |
$8,888 1,128 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $4,492 Cost: $500 |
- | - | - | - | - | - | $4,492 | 3,975,159 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,492 3,975,159 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,914 Cost: - |
$2,016 | 59,280 | $898 | 228 | - | - | - | - | - | - |
$2,016 59,280 kWh |
$898 228 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,566 Cost: $3,665 |
- | - | - | - | $1,566 | 216 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,566 216 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,204 Cost: $2,418 |
$920 | 18,720 | $284 | 36 | - | - | - | - | - | - |
$920 18,720 kWh |
$284 36 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $909 Cost: - |
$389 | 11,440 | $520 | 66 | - | - | - | - | - | - |
$389 11,440 kWh |
$520 66 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $180,743 Cost: $7,705 |
$12,448 | 357,760 | $14,817 | 1,994 | $1,566 | 216 | $4,492 | 3,975,159 | $147,420 | - | $12,448 357,760 kWh |
$14,817 1,994 kW-months/year |
$1,566 216 MMBtu |
$4,492 3,975,159 Tgal |
$147,420 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $161,974 Cost: $3,540 |
$10,043 | 287,040 | $4,511 | 572 | - | - | - | - | $147,420 | - | $10,043 287,040 kWh |
$4,511 572 kW-months/year |
- - MMBtu |
- - Tgal |
$147,420 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |