Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2005 |
Principal Product | Aluminum and zinc die castings |
NAICS | 331523 - Nonferrous Metal Die-Casting Foundries |
SIC | 3363 - Aluminum Die-castings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 208 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 21,000,000 Pieces |
Production Hrs. Annual | 4,050 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $332,851 | 8,938,455 | kWh | $0.04 |
Electricity Demand | $396,931 | 22,596 | kW-months/year | $17.57 |
Natural Gas | $1,110,171 | 118,841 | MMBtu | $9.34 |
TOTAL ENERGY COSTS | $1,895,802 | |||
RECOMMENDED SAVINGS* | $722,726 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $410,599 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $222,216 Cost: $3,730 |
- | - | - | - | - | - | $222,216 | 26,143 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$222,216 26,143 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $157,981 Cost: $295,540 |
- | - | - | - | - | - | $157,981 | 18,586 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$157,981 18,586 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $113,135 Cost: $17,165 |
- | - | - | - | - | - | $113,135 | 13,310 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$113,135 13,310 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $93,662 Cost: $72,100 |
- | - | - | - | - | - | $93,662 | 11,019 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$93,662 11,019 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $27,707 Cost: $93,840 |
$7,764 | 287,064 | $18,422 | 852 | - | - | - | - | $1,521 | - |
$7,764 287,064 kWh |
$18,422 852 kW-months/year |
- - $ |
- - MMBtu |
$1,521 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7314 REDUCE VENTILATION AIR |
Savings: $26,800 Cost: - |
- | - | - | - | - | - | $26,800 | 3,162 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$26,800 3,162 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $19,788 Cost: $4,000 |
- | - | - | - | - | - | $19,788 | 2,328 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$19,788 2,328 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $19,593 Cost: $40,000 |
- | - | - | - | - | - | $19,593 | 2,305 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$19,593 2,305 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $19,470 Cost: $3,940 |
$6,470 | 239,600 | $13,000 | 600 | - | - | - | - | - | - |
$6,470 239,600 kWh |
$13,000 600 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,819 Cost: $12,560 |
$4,819 | 58,767 | - | - | - | - | - | - | - | - |
$4,819 58,767 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2514 COVER OPEN TANKS |
Savings: $4,429 Cost: $1,200 |
- | - | - | - | - | - | $4,429 | 521 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$4,429 521 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,280 Cost: $736 |
$292 | 10,800 | $520 | 24 | - | - | $3,468 | 408 | - | - |
$292 10,800 kWh |
$520 24 kW-months/year |
- - $ |
$3,468 408 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $3,679 Cost: - |
$1,338 | 49,572 | $2,341 | 108 | - | - | - | - | - | - |
$1,338 49,572 kWh |
$2,341 108 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $1,948 Cost: $500 |
$648 | 24,000 | $1,300 | 60 | - | - | - | - | - | - |
$648 24,000 kWh |
$1,300 60 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.8118 CHECK FOR ACCURACY OF UTILITY / POWER METERS |
Savings: $1,554 Cost: - |
- | - | - | - | $1,554 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,554 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,253 Cost: - |
$1,253 | 46,400 | - | - | - | - | - | - | - | - |
$1,253 46,400 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $412 Cost: $960 |
$412 | 15,245 | - | - | - | - | - | - | - | - |
$412 15,245 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $722,726 Cost: $546,271 |
$22,996 | 731,448 | $35,583 | 1,644 | $1,554 | - | $661,072 | 77,782 | $1,521 | - | $22,996 731,448 kWh |
$35,583 1,644 kW-months/year |
$1,554 - $ |
$661,072 77,782 MMBtu |
$1,521 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $410,599 Cost: $189,126 |
$15,878 | 467,848 | $21,283 | 984 | $1,554 | - | $370,363 | 43,581 | $1,521 | - | $15,878 467,848 kWh |
$21,283 984 kW-months/year |
$1,554 - $ |
$370,363 43,581 MMBtu |
$1,521 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Ancillary Material Cost |