Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2010 |
Principal Product | gray and ductile castings |
NAICS | 331511 - Iron Foundries |
SIC | 3321 - Gray And Ductile Iron Foundries |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 463,000 |
Annual Production | 29,974 Tons |
Production Hrs. Annual | 2,640 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,601,455 | 40,287,654 | kWh | $0.04 |
Electricity Demand | $900,818 | 11,722 | kW-months/year | $76.85 |
Natural Gas | $453,649 | 46,221 | MMBtu | $9.81 |
TOTAL ENERGY COSTS | $2,955,922 | |||
RECOMMENDED SAVINGS* | $1,933,865 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $48,864 Cost: $143,000 |
- | - | - | - | $48,864 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$48,864 - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9121 INSTALL WIND POWERED ELECTRIC GENERATOR |
Savings: $1,443,350 Cost: $3,000,000 |
$1,443,350 | 5,281,037 | - | - | - | - | - | - | - | - | - | - |
$1,443,350 5,281,037 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,706 Cost: $15,238 |
$7,239 | 136,322 | $2,349 | 24 | - | - | - | - | $(-882) | - | - | - |
$7,239 136,322 kWh |
$2,349 24 kW-months/year |
- - $ |
- - MMBtu |
$(-882) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $8,478 Cost: $10,195 |
$8,478 | 159,662 | - | - | - | - | - | - | - | - | - | - |
$8,478 159,662 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,762 Cost: $6,380 |
$6,154 | 98,963 | $5,255 | 9 | - | - | - | - | $353 | - | - | - |
$6,154 98,963 kWh |
$5,255 9 kW-months/year |
- - $ |
- - MMBtu |
$353 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,468 Cost: $4,640 |
$3,727 | 70,182 | $654 | 7 | - | - | - | - | $87 | - | - | - |
$3,727 70,182 kWh |
$654 7 kW-months/year |
- - $ |
- - MMBtu |
$87 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,897 Cost: $20 |
$1,696 | 31,944 | $1,201 | 12 | - | - | - | - | - | - | - | - |
$1,696 31,944 kWh |
$1,201 12 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $81,554 Cost: $20,000 |
$70,317 | 1,324,210 | $11,237 | 113 | - | - | - | - | - | - | - | - |
$70,317 1,324,210 kWh |
$11,237 113 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $49,948 Cost: $16,000 |
$37,712 | 710,208 | $12,236 | 123 | - | - | - | - | - | - | - | - |
$37,712 710,208 kWh |
$12,236 123 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $14,595 Cost: $1,500 |
$10,705 | 201,600 | $3,890 | 39 | - | - | - | - | - | - | - | - |
$10,705 201,600 kWh |
$3,890 39 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $14,160 Cost: $2,000 |
$14,160 | 266,667 | - | - | - | - | - | - | - | - | - | - |
$14,160 266,667 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $486 Cost: $540 |
$367 | 6,912 | $119 | 1 | - | - | - | - | - | - | - | - |
$367 6,912 kWh |
$119 1 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2514 COVER OPEN TANKS |
Savings: $80,740 Cost: $1,600 |
$80,740 | 1,523,405 | - | - | - | - | - | - | - | - | - | - |
$80,740 1,523,405 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $61,285 Cost: $5,152 |
$61,285 | 1,156,320 | - | - | - | - | - | - | - | - | - | - |
$61,285 1,156,320 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT |
Savings: $43,001 Cost: $1,243,001 |
- | - | - | - | - | - | $43,001 | 4,383 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$43,001 4,383 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.1123 INSTALL AUTOMATIC STACK DAMPER |
Savings: $22,399 Cost: $500 |
- | - | - | - | - | - | $22,399 | 2,283 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$22,399 2,283 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.2514 COVER OPEN TANKS |
Savings: $8,613 Cost: $17,226 |
- | - | - | - | - | - | $8,613 | 878 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,613 878 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $18,106 Cost: $36,212 |
- | - | - | - | - | - | - | - | - | - | $18,106 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$18,106 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
19: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,081 Cost: $11,700 |
$6,081 | 114,514 | - | - | - | - | - | - | - | - | - | - |
$6,081 114,514 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,372 Cost: $11,000 |
$4,372 | 82,336 | - | - | - | - | - | - | - | - | - | - |
$4,372 82,336 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,933,865 Cost: $4,545,904 |
$1,756,383 | 11,164,282 | $36,941 | 328 | $48,864 | - | $74,013 | 7,544 | $(-442) | - | $18,106 | - | $1,756,383 11,164,282 kWh |
$36,941 328 kW-months/year |
$48,864 - $ |
$74,013 7,544 MMBtu |
$(-442) - $ |
$18,106 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Water Consumption |