Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2011 |
Principal Product | Gray and Ductile Castings |
NAICS | 331511 - Iron Foundries |
SIC | 3321 - Gray And Ductile Iron Foundries |
Sales | $1,000,000-$5,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 1,100 Tons |
Production Hrs. Annual | 2,500 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,815 | 549,455 | kWh | $0.09 |
Electricity Demand | $28,748 | 614 | kW-months/year | $46.82 |
Electricity Fees | $4,964 | - | $ | - |
Natural Gas | $26,565 | 2,225 | MMBtu | $11.94 |
TOTAL ENERGY COSTS | $111,133 | |||
RECOMMENDED SAVINGS* | $11,364 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,398 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $688 Cost: $3,315 |
$519 | 6,024 | $137 | 2 | - | - | $32 | - |
$519 6,024 kWh |
$137 2 kW-months/year |
- - MMBtu |
$32 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $251 Cost: $860 |
$185 | 2,153 | $49 | 1 | - | - | $17 | - |
$185 2,153 kWh |
$49 1 kW-months/year |
- - MMBtu |
$17 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $197 Cost: $665 |
$158 | 1,835 | $42 | 1 | - | - | $(-3) | - |
$158 1,835 kWh |
$42 1 kW-months/year |
- - MMBtu |
$(-3) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $408 Cost: $25 |
$323 | 3,750 | $85 | 2 | - | - | - | - |
$323 3,750 kWh |
$85 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $211 Cost: $25 |
$167 | 1,935 | $44 | 1 | - | - | - | - |
$167 1,935 kWh |
$44 1 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION |
Savings: $3,027 Cost: $6,500 |
$2,624 | 30,472 | $403 | 7 | - | - | - | - |
$2,624 30,472 kWh |
$403 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $6,582 Cost: $2,349 |
- | - | - | - | $6,582 | 551 | - | - |
- - kWh |
- - kW-months/year |
$6,582 551 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,364 Cost: $13,739 |
$3,976 | 46,169 | $760 | 14 | $6,582 | 551 | $46 | - | $3,976 46,169 kWh |
$760 14 kW-months/year |
$6,582 551 MMBtu |
$46 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,398 Cost: $3,064 |
$648 | 7,520 | $171 | 4 | $6,582 | 551 | $(-3) | - | $648 7,520 kWh |
$171 4 kW-months/year |
$6,582 551 MMBtu |
$(-3) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |