Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2014 |
Principal Product | PV Modules |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $100,000,000-$500,000,000 |
# of Employees | 1,100 |
Plant Area (Sq.Ft.) | 540,000 |
Annual Production | 2,000,000 Pieces |
Production Hrs. Annual | 8,712 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,265,856 | 67,315,973 | kWh | $0.03 |
Electricity Demand | $94,332 | 10,014 | kW-months/year | $9.42 |
Natural Gas | $67,992 | 8,499 | MMBtu | $8.00 |
TOTAL ENERGY COSTS | $2,428,180 | |||
RECOMMENDED SAVINGS* | $76,923 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $62,557 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2623 MINIMIZE CONDENSER COOLING WATER TEMPERATURE |
Savings: $13,929 Cost: - |
$8,334 | 247,588 | $5,595 | 594 | - | - | - | - |
$8,334 247,588 kWh |
$5,595 594 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $5,296 Cost: - |
- | - | - | - | $5,296 | 662 | - | - |
- - kWh |
- - kW-months/year |
$5,296 662 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,682 Cost: - |
$2,662 | 79,071 | $1,020 | 108 | - | - | - | - |
$2,662 79,071 kWh |
$1,020 108 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,046 Cost: - |
$2,202 | 65,424 | $844 | 90 | - | - | - | - |
$2,202 65,424 kWh |
$844 90 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $50,533 Cost: $188,160 |
$33,667 | 1,000,182 | $12,906 | 1,370 | - | - | $3,960 | - |
$33,667 1,000,182 kWh |
$12,906 1,370 kW-months/year |
- - MMBtu |
$3,960 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $437 Cost: $2,350 |
$316 | 9,385 | $121 | 13 | - | - | - | - |
$316 9,385 kWh |
$121 13 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,923 Cost: $190,510 |
$47,181 | 1,401,650 | $20,486 | 2,176 | $5,296 | 662 | $3,960 | - | $47,181 1,401,650 kWh |
$20,486 2,176 kW-months/year |
$5,296 662 MMBtu |
$3,960 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $62,557 Cost: $188,160 |
$38,531 | 1,144,677 | $14,770 | 1,568 | $5,296 | 662 | $3,960 | - | $38,531 1,144,677 kWh |
$14,770 1,568 kW-months/year |
$5,296 662 MMBtu |
$3,960 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |